137
Chapter 5.  Handling the CU-6000  (Option)
5.4 Communicating with the Host
Computer
5.4.1 Setting the Transmission Speed of the CU-6000
Set the transmission speed of the CU-6000 to the same value as that of the BHT-6000
and the host computer, by using the DIP switch provided on the bottom of the CU-
6000.
(1)
Turn the CU-6000 upside down.
(2)
Remove the protection sheet of the DIP switch from the CU-6000.
(3)
Set the selectors of the DIP switch as shown below.
For 115,200 bps
For 57,600 bps
ON
OFF
1   2   3
OFF
ON
OFF
1   2   3
OFF
For 38,400 bps
For 19,200 bps
ON
OFF
1   2   3
OFF
ON
OFF
1   2   3
OFF
For 9,600 bps (Factory setting)
Protection sheet
(Inside this sheet
is a DIP switch.)
(4)
Reinstall the protection sheet.
Do not set the DIP switch to any configurations other than one of the five shown
above.
NOTE
5.4.2 Interface Cable Connection
(1)
Make sure that both the CU-6000 and the host computer are turned off.
(2)
Connect the 25-pin plug (Dsub-25P) of the interface cable to the RS-232C interface
port of the CU-6000.
Bottom View
RS-232C interface
cable
(3)
Connect the other end of the interface cable to the host computer.
ON
OFF
1   2   3
OFF