Delta Tau TURBO CLIPPER DRIVE Manual Do Utilizador
Turbo Clipper Drive User Manual
Power board: Wiring, Software Setup
18
Wiring The E-Stop, And Reset Switch
The E-Stop button should be a normally-closed switch, so
that the circuit is closed when it is released and open when
it is pressed.
The Reset button should be a normally-open switch before
revision 103, so that the circuit is open when it is released
and closed when it is pressed. Revision 103 and after the
type of Reset button can be selectable via jumper E4.
that the circuit is closed when it is released and open when
it is pressed.
The Reset button should be a normally-open switch before
revision 103, so that the circuit is open when it is released
and closed when it is pressed. Revision 103 and after the
type of Reset button can be selectable via jumper E4.
Note
It is recommended to wire the E-
Stop in series with the reset
circuit, so if the machine is in an
emergency stop condition, the
reset cannot be activated and has
no practical use.
Stop in series with the reset
circuit, so if the machine is in an
emergency stop condition, the
reset cannot be activated and has
no practical use.
E-STOP
Normally
Open
Normally
Closed
RESET
1
2
3
4
J13
Emergency Stop, Reset Jumpers Summary
The following table summarizes the E-Stop and Reset features. The hard E-Stop designates the
actual hardware E-Stop button. The soft E-Stop designates the software controllable E-Stop bit:
actual hardware E-Stop button. The soft E-Stop designates the software controllable E-Stop bit:
Board
Jumper
Function
Default
Power
E1
Remove to enable the hard E-Stop function.
Install to disable the hard E-Stop function.
Not Installed
Power
E2
Remove to enable hard & soft E-Stop functions.
Install to disable hard & soft E-Stop functions.
Not Installed
Power
E3
Remove to enable the soft E-Stop function.
Install to disable the soft E-Stop function
(Soft E-Stop bit has to be set, and saved to 1).
Not Installed
Power
E4
Remove jumper to use normally-open Reset switch
between pin 1 and 2 of J13.
Install jumper to use normally-closed Reset switch
between pin 1 and 2 of J13.
between pin 1 and 2 of J13.
Install jumper to use normally-closed Reset switch
between pin 1 and 2 of J13.
Not Installed
Breakout
J36
Install jumper to disable the GPO E-Stop automatic
feature (outputs unaffected by E-Stop status).
feature (outputs unaffected by E-Stop status).
Remove Jumper to enable the GPO E-Stop
automatic feature (turn outputs off when in E-Stop)
Installed
Breakout
J39
Jump 1 to 2 to use User Flag 4 as an E-Stop status
in software.
in software.
Jump 2 to 3 to use User Flag 4 as a general purpose
user input.
Jumpered
1-2