Delta Tau GEO BRICK LV Manual De Referência

Página de 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Memory and I/O Map 
 501 
Y:$000xB7/37 
 
Motor estimated rotor magnetization current  
X:$000xB8/38 
 
Motor commanded quadrature current (0 for microstep) 
Y:$000xB8/38 
 
Motor commanded direct current (0 for microstep) 
X:$000xB9/39 
 
Motor actual quadrature current 
Y:$000xB9/39 
 
Motor actual direct current 
X:$000xBA/3A 
 
Motor current-loop back path proportional gain (Ixx76) 
Y:$000xBA/3A 
 
Motor current-loop forward path proportional gain (Ixx62) 
X:$000xBB/3B 
 
Motor commutation table pointer 
Y:$000xBB/3B 
 
Motor current-loop integral gain (Ixx61) 
X:$000xBC/3C 
 
Motor quadrature current loop integrator output 
Y:$000xBC/3C 
 
Motor direct current loop integrator output 
X:$000xBD/3D 
 
Motor commutation table pointer offset (Ixx55) 
Y:$000xBD/3D 
 
Motor PWM scale factor (Ixx66) 
X:$000xBE/3E 
 
Motor command output address (Ixx02) 
Y:$000xBE/3E 
 
Motor delay compensation gain (Ixx56) 
X:$000xBF/3F 
 
Motor (Quadrature/torque) command value (includes bias) 
Y:$000xBF/3F 
 
Motor (Quadrature/torque) command bias (from TCOMP table) 
Motor # 
Address 
$0000Cx 
$00014x 
$0001Cx 
$00024x 
$0002Cx 
$00034x 
$0003Cx 
$00044x 
Motor # 
10 
11 
12 
13 
14 
15 
16 
Address 
$0004Cx 
$00054x 
$0005Cx 
$00064x 
$0006Cx 
$00074x 
$0007Cx 
$00084x 
Motor # 
17 
18 
19 
20 
21 
22 
23 
24 
Address 
$0008Cx 
$00094x 
$0009Cx 
$000A4x 
$000ACx 
$000B4x 
$000BCx 
$000C4x 
Motor # 
25 
26 
27 
28 
29 
30 
31 
32 
Address 
$000CCx 
$000D4x 
$000DCx 
$000E4x 
$000ECx 
$000F4x 
$000FCx 
$00104x 
X:$000xC0/40 
 
Motor fatal following error limit (Ixx11) 
Y:$000xC0/40 
 
Motor status bits 
 
(Second word returned on ? command.  See X:$000xB0/30 for first word) 
 
(Refer to ? specification in On-line Commands for detailed description of bit meanings) 
 
 
 
Background-check in-position  
 
 
 
Warning following error limit exceeded 
 
 
 
Fatal following error limit exceeded 
 
 
 
Amplifier fault error 
 
 
 
Backlash direction flag 
 
 
 
I
2
T Amplifier fault error 
 
 
 
Integrated fatal following error 
 
 
 
Trigger move 
 
 
 
Phasing reference error 
 
 
 
Phasing reference in progress 
 
 
 
10 
Home complete 
 
 
 
11 
Stopped on actual position limit 
 
 
 
12 
Stopped on desired position limit 
 
 
 
13 
Foreground-check in-position 
 
 
 
14 
HomeZ flag (gets set =1 on a HOMEZ command; user must reset it to 0) 
 
 
 
15 
Assigned to C.S. (=1 when motor is assigned to a C.S.) 
 
 
 
16-18  Coordinate definition (0=none, 1=A, 2=B, 3=C,  4=UVW, 5=I, 7=XYZ) 
 
 
 
19 
Reserved for future use 
 
 
 
20-23  (Number of C.S. - 1) in which this motor is defined