Remove the terminal block access cover 
on the upper back of the dryer. Install a 
UL-listed strain relief into the power cord 
through-hole; then thread a UL-listed, 
30A, 
240V, 4-wire, #10 AWG-minimum copper 
conductor power cord through the 
strain relief.
1
Transfer the dryer’s ground wire from behind 
the green ground screw to the center screw 
of the terminal block. Attach the two hot 
leads of the power cord to the outer terminal 
block screws. Attach the white neutral wire 
to the center terminal block screw. Attach the 
power cord ground wire to the green ground 
screw. TIGHTEN ALL SCREWS SECURELY. 
Reinstall the terminal block access cover.
2
UL-Listed 
Strain Relief
UL-Listed 
4-Wire 
Power Cord
Terminal 
Block
Ground Screw
Neutral 
(White)
 Hot
 (Black)
Power Cord 
Ground Wire
Hot 
(Red)
CONNECTING ELECTRIC DRYERS 
(cont.)
Four-Wire Connection for Electric Dryers: Power Cord
•  A 4-wire connection is required for all mobile 
and manufactured home installations, as well 
as all new construction after January 1, 1996. 
•  A UL-listed strain relief is required. 
•  Use a 
30-amp, 240V, UL-listed power cord 
with #10 AWG-minimum copper conductor 
and closed loop or forked terminals with 
upturned ends.
w
WARNING: 
• Connect the power cord to the terminal block. Each colored wire should be connected 
to same color screw. Wire color indicated on manual is connected to the same color 
screw in block. Failure to follow these instructions may result in a short or overload.
• Grounding through the neutral conductor is prohibited for: (1) new branch-circuit 
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local 
codes prohibit grounding through the neutral conductor.