Broan RMIP45 Manual Do Utilizador

Página de 16
WARNING
WARNING
- 2 -
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1.
Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer at the address or telephone number 
listed in the warranty.
2.
Before servicing or cleaning unit, switch power off 
at service panel and lock service disconnecting 
means to prevent power from being switched on 
accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done 
by qualified personnel in accordance with all 
applicable codes and standards, including fire-rated
construction codes and standards.
4.
Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of 
fuel burning equipment to prevent backdrafting. 
Follow the heating equipment manufacturer’s 
guidelines and safety standards such as those 
published by the National Fire Protection 
Association (NFPA), and the American Society for 
Heating, Refrigeration and Air Conditioning 
Engineers (ASHRAE), and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the 
outdoors.
7.
Do not use this unit with any solid-state speed 
control device other than RMIPWC optional wall 
mounted control.
8.
To reduce the risk of fire, use only metal ductwork.
9.
This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
a)
Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or 
medium settings.
b)
Always turn hood ON when cooking at high heat or 
when cooking flaming foods.
c)
Clean ventilating fans frequently. Grease should 
not be allowed to accumulate on fan or filter.
d)
Use proper pan size. Always use cookware 
appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING*:
1.
SMOTHER FLAMES with a close-fitting lid,
cookie sheet or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. IF 
THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2.
NEVER PICK UP A FLAMING PAN – You may
be burned.
3.
DO NOT USE WATER, including wet dishcloths or 
towels – This could cause a violent steam explosion.
4.
Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and 
you know how to operate it.
B. The fire is small and contained in the area 
where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1.
For general ventilating use only. Do not use to 
exhaust hazardous or explosive materials and vapors.
2.
To avoid motor bearing damage and noisy and/or 
unbalanced impellers, keep drywall spray, 
construction dust, etc. off power unit.
3.
Your insert motor has a thermal overload which will 
automatically shut off the motor if it becomes 
overheated. The motor will restart when it cools 
down. If the motor continues to shut off and restart, 
have the insert serviced.
4.
The minimum hood distance above cooktop must 
not be less than 24”. A maximum of 30” above 
cooktop is highly recommended for best capture of 
cooking impurities.
5.
Two installers are recommended because of the 
large size and weight of this unit.
6.
To reduce the risk of fire and to properly exhaust 
air, be sure to duct air outside – Do not exhaust air 
into spaces within walls or ceiling or into attics, 
crawl space or garage. 
7.
This product is equipped with a thermostat which 
may start blower automatically. To reduce the risk 
of injury and to prevent power from being switched 
on accidentally, switch power off at service panel 
and lock or tag service panel.
8.
Because of the high exhausting capacity of this 
unit, you should make sure enough air is entering 
the house to replace exhausted air by opening a 
window close to or in the kitchen.
9.
To reduce the risk of fire and electrical shock, the 
Broan Elite models RMIP33 and RMIP45 must be 
installed only with Broan interior blower models P5 
or P8; Broan exterior models 331H, 332H, 335 or 
336; Broan in-line blowers models HLB3, HLB6, 
HLB9, HLB11. Other blowers cannot be substituted.
(Blowers sold separately).
10.
Use with approved cord-connection kit only.
11.
Please read specification label on product for 
further information and requirements.
!
!