MODEL  EI5936SS
Page 2
FRONT
HOOD
CENTERLINE
HOOD
CENTERLINE
5”
2”
3½”
3½”
HOUSE WIRING
IN THIS AREA
FRONT
HOOD
CENTERLINE
HOOD
CENTERLINE
DUCT
CENTERLINE
OFFSET 1” TO
REAR OF HOOD
8” MINIMUM
8½”
ON CENTER
INSTALL THE DUCTWORK 
(Ducted Hoods Only)
1.  Decide where the ductwork will run between the hood and
the outside.
2.  A straight, short duct run will allow the hood to perform most
efficiently.
3.  Long  duct  runs,  elbows  and  transitions  will  reduce  the
performance  of  the  hood.  Use  as  few  of  them  as  possible.
Larger  ducting  may  be  required  for  best  performance  with
longer duct runs.
4.  Install wall cap or roof cap. Connect round metal ductwork to
cap and work back towards the hood location. Use duct tape
to seal the joints between ductwork sections.
PLAN THE INSTALLATION
The  minimum  hood  distance  above  cooktop  MUST  NOT  BE
LESS than 24”.
A  maximum  of  36”  above  cooktop  is  recommended  for  best
capture of cooking impurities.
Distances  over  36”  are  at  the  installer  and  users  discretion;
providing that the ceiling height permits.
INSTALL THE CEILING SUPPORT
1.  Construct wood framing that is flush with interior surface of
the ceiling joists.
NOTE
Hood  distance  above  cooktop  is:  Minimum  24”,  Maximum
36”.  9-10  ft.  ceilings  may  require  Flue  Extension  Model
FXNE59SS,  depending  on  installation  height  (purchase
separately).  Discard  the  upper  and  lower  flues,  mounting
frame, and trim strips supplied with your hood and replace
them with Flue Extension Model FXNE59SS.
2.  Finish opening to match surrounding ceiling carefully marking
framing location.
INSTALL THE WIRING
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short  circuit,  grounding  reduces  the  risk  of  electric  shock  by
providing an escape wire for the electric current.
Position the electrical (house wiring) within the space covered by
the decorative flue and where it will not interfere with the round
duct. Make sure the length of the house wiring is a minimum of 5
feet. It may be shortened after hood is installed at correct height
and electrical connection is made.
ROOF
 
CAP
DECORATIVE
FLUES
EAVE
VENT
6” ROUND
ELBOWS
6” ROUND
DUCT
HOOD
24” TO 36” ABOVE
COOKING SUFACE
HOOD
CENTER
LINE
DUCT CENTER LINE
(1” to rear of hood centerline)