Bosch Appliances Home Security System ICP-CC404 Manual Do Utilizador

Página de 98
ICP-CC404 | Installation Guide | 10.0   Dialer Reporting Formats 
 
 
44 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
 
Table 36: 
4+2 Express Transmission Code 
Descriptions 
 
Code 
Description 
SSSS 
Subscriber ID Number 
A Alarm 
C
H
 
Channel Number 
0 Zero 
Trouble 
B Bypass 
AC Fail Code 1
st
 digit 
AC 
AC Fail Code 2
nd
 digit 
Low Battery Code 1
st
 digit 
L
B
 
Low Battery Code 2
nd
 digit 
Open 
C Close 
User Number 
Alarm Restore Code 
TR 
Trouble Restore Code 
B
R
 
Bypass Restore Code 
E
R
 
AC Fail Restore Code 1
st
 digit 
AC
R
 
AC Fail Restore Code 2
nd
 digit 
L
R
 
Low Battery Restore Code 1
st
 digit 
L
BR
 
Low Battery Restore Code 2
nd
 digit 
Duress Code 1
st
 digit 
D
0
 Duress 
Code 
2
nd
 digit 
Panic Code 1
st
 digit 
P
CH
 Panic 
Code 
2
nd
 digit 
T
E
 
Test Code 
10.1.4 Basic 
Pager 
Reporting Format 
Although Basic Pager Format requires some 
interpretation of the numbers that appear on the 
display, it can differentiate between 1000 different 
control panels if a number of control panels report to 
the one pager. 
To set up Receiver 1 for basic pager reporting: 
1.  Program the Basic Pager’s access telephone 
number in Locations 000 to 015 (refer to Section 
11.1 Primary Telephone Number for Receiver 1 and 
Receiver 2
 on page 46). 
2.  Program the Subscriber ID Number in Locations 
034 to 039 (refer to Section 11.5 Subscriber ID 
Number for Receiver 1 and Receiver 2
 on page 47). 
3.  Select Pager Handshake (Option 5) in 
Location 032 (refer to Section 11.3 Handshake Tone 
for Receiver 1 and Receiver 2
 on page 47).  
4.  Program Basic Pager Format (Option 5) in 
Location 033 (refer to Section 11.4 Transmission 
Format for Receiver 1 and Receiver 2
 on page 47). 
To set up Receiver 2 for basic pager reporting: 
1.  Program the Basic Pager’s access telephone 
number in Locations 040 to 055 (refer to Section 
11.1 Primary Telephone Number for Receiver 1 and 
Receiver 2
 on page 46). 
2.  Program the Subscriber ID Number in Locations 
074 to 079 (refer to Section 11.5 Subscriber ID 
Number for Receiver 1 and Receiver 2
 on page 47). 
3.  Select Pager Handshake (Option 5) in Location 
072 (refer to Section 11.3 Handshake Tone for 
Receiver 1 and Receiver 2
 on page 47).  
4.  Program Basic Pager Format (Option 5) in 
Location 073 (refer to Section 11.4 Transmission 
Format for Receiver 1 and Receiver 2
 on page 47). 
The example in Figure 6 shows: 
•  Transmission from Subscriber ID Number 5678 
•  Zone 2 in alarm 
•  Zone 3 manually isolated 
•  The system is armed 
•  The Panic Zone is normal 
•  The AC is connected 
•  There is no fault condition.