B-CONTROL  FADER  BCF2000-WH
Pitch Bend:
Pitch  bend  is  assignable  to  only  one  CONTINUOUS  element.
Since this is a type of command with its own status byte, selecting
a MIDI channel (Encoder 2) and Range (Encoder 4) is sufficient.
After Touch:
Normally, “ALL” is selected here. This means that After Touch
affects all notes equally (“Channel Pressure”). If you want to use
a polyphonic After Touch (“Key Pressure”), the single note on
which After Touch should have an effect can be selected using
encoder 3. Since this process is only supported by a few tone
generators, channel After Touch will be best most of the time.
When a switch element has been selected, an “on” and “off” value
can also be set (release dynamic). Therefore, you can limit the
modulation range (FX depth) using After Touch.
MMC:
MIDI Machine Control data is only assignable to button elements.
Encoder 4 (Value 1) sets “Locate Time” hour and minute values,
while encoder 5 (Value 2) sets seconds and frames. The Locate
Position is always sent before the MMC command. We therefore
have the following logic-switching sequence:
If the “Locate” parameter has been selected, the sequencer or
hard drive recorder always jumps to the set position. If “Play” has
been  selected  as  the  parameter  (for  a  button),  the  sequencer
always starts from the set locator point as soon as the button is
pressed.  “Rewind”  always  begins  at  the  chosen  locator  point.
Select the frame rate with encoder 6: 24, 25, 30 (non-drop), 30d
(drop frame) or “off” (in this case only the MMC message is sent,
without any information of the locate position).
GS/XG:
Encoder  3  directly  selects  the  most  important  “Main  Control”
parameters.  The  display  indicates  them  as  a  (shortened)  text
(table  4.2).  In  this  case,  these  are  CCs  or  NRPNs  (no  SysEx
data).
Table 4.3: GS/XG Parameter Main Controls
Encoders 4 and 5 let you confine or invert each controllers’ value
range.
4.5 Settings in the global setup menu
Settings that have an effect on all presets are made in the global
setup menu.
s
Keep the EDIT key pressed and at the same time press the
STORE key.
s
You are now in the global setup menu, and can let go of
both keys.
s
Now, turn the push encoders 1 to 8 to get the desired setting.
This is how the push encoders are allocated:
4. OPERATION
(QFRGHU
)XQFWLRQ
6HOHFW
1
Operating Mode
U-1 ... U-4, S-1 ... S-4
2
Global RX Channel
Off, 1 ... 16
3
Footswitch
Auto/Normal/Inverted
4
Start-Preset
1 ... 32, Last
5
Device ID
1 ... 16
6
SysEx Dump
Single/All
7
-
-
8
MIDI Data Interval
(ms)
Table 4.4: Push encoder allocation in global setup menu
s
To exit the global setup menu, press EXIT.
+
The  settings  in  the  global  setup  menu  take  effect
immediately and do not have to be separately stored.
Operating Mode:
The  operating  modes  are  described  in  chapter  4.1.  You  can
select USB modes U-1 to U-4 and stand-alone modes S-1 to S-4.
Global RX Channel:
The B-CONTROL receives program change commands on this
channel.
Footswitch type:
Because there are different kinds of footswitches (depending on
their switching behavior), the polarity of the footswitch connector
can be set (normal/inverted), or it can be automatically detected
during power startup (auto recognition).
Start Preset Number:
Each of the 32 presets can be selected as the startup preset.
Additionally, with the “Last” function, at startup you have the option
to always load the preset that was used last.
Device ID Number:
You should change the ID number settings only if you work with
several  BCF2000-WHs  at  the  same  time,  and  problems  with
recognizing  the  correct  device  start  occurring  during  a  SysEx
Dump procedure.
+
Please  keep  in  mind  that  SysEx  Dumps  can  only  be
received at the device number to which they were sent!
SysEx Dump Select:
Turning push encoder 6 lets you select between the current preset
(single) or the entire memory contents of the 32 presets (all) should
be sent as a SysEx dump. One press on encoder 6 triggers the
dump.
To receive a SysEx dump, you don’t have to change any settings
on  your  equipment.  If  you  send  a  single  preset  to  the
B-CONTROL, the data is written to a temporary memory; to be
stored permanently, the data has to be stored on a storage slot
of your choice (preset store function).
+
WARNING:  If  you  send  an  “ALL-Dump”  to  the
B-CONTROL,  the  entire  memory  contents  are  directly
overwritten! No request to confirm will be made, and
the memory has no redundant safety function!
s
To cancel a SysEx dump, press the EXIT key.
MIDI Data Interval:
This is where you adjust the data transmission rate. This setting
only has an effect on MIDI data packs such as SysEx dumps and
not on controlling of MIDI commands (they are carried out in real
time anyway). The transmission rate is adjustable in milliseconds.