Figure 8a. – Interrupted ignition, valve-on delay only 
(no motor-off delay)
Figure 8b. – Interrupted ignition, valve-on delay and 
motor-off delay
SAFETY AND
OPERATING
LIMITS
LIMIT
L1
L2 (VLV)
VALVE
L2
MOTOR
L2 (MTR)
L2 (IGN)
IGNITER
CAD
CELL
MOTOR
IGNITER
W
R
80
70
60
50
50
70
80
60
OIL VALVE
CAD CELL
THERMOSTAT
TR
TW
TR-TW
JUMPER
TR-TW TERMINALS
LOCATED ON OPPOSITE 
SIDE OF CONTROL
L1
L2
SAFETY AND
OPERATING
LIMITS
LIMIT
L1
L2 (VLV)
VALVE
L2
MOTOR
L2 (MTR)
L2 (IGN)
IGNITER
CAD
CELL
MOTOR
IGNITER
W
R
80
70
60
50
50
70
80
60
OIL VALVE
CAD CELL
THERMOSTAT
TR
TW
TR-TW
JUMPER
TR-TW TERMINALS
LOCATED ON OPPOSITE 
SIDE OF CONTROL
L1
L2
LIMIT
L1 - LIMIT 
JUMPER
Table 2 - Reset Button Operation
If the burner is in the 
below state:
Pushing the reset button will:
Button Click
(press < 1 second)
Button Hold
(press > 1 second)
Button Hold 
(press 15+ seconds)
Lockout
Reset from Soft Lockout
Reset from Restricted (Hard) 
Lockout
Valve-on Delay, Trial for 
Ignition, Ignition Carryover
Go to Pump Prime (see 
“Priming the Pump” above)
Disable the Burner:
Any time the burner is running, 
press and hold the reset button 
to disable the burner.  The 
burner will remain off as long 
as the button is held.
Enables Pump Priming: 
After the reset button has been 
held for 15 seconds, the button 
can then be clicked during the 
next ignition sequence to enter 
Pump Prime mode.
Run (igniter is shut off)
No action
Motor-Off Delay,
Standby
No action
Pump Prime
No action
Exit Pump Prime mode and return to Standby
Table 3 - Status Lights
Light Color
On Continuously
Flashing
Red
Restricted (Hard) Lockout
Soft Lockout
Green
Flame Sensed during normal operation (Could 
be stray light during standby)
Recycle
Yellow
Control is in Pump Prime mode or
Reset button currently held for 15+ seconds.
N/A
Reset Button Operation
Table 2  explains what action the control will take when the reset button is pressed for different lengths of time during 
the various burner operating states.
Section: Burner Controls