BEA LO Linx 80.0240.04 Manual Do Utilizador

Página de 18
Pre-wired
switch
assembly
DC
MOTOR
-
+
RED
RED
BODYGUARD (Y) HARNESS
USED FOR DUAL-EGRESS
APPLICATIONS
*
SIZE:
DRAWN BY:
TITLE: LO-LINX SYSTEM
BESAM ETIK CONTROL
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA  15275
PHONE: (412) 249-4100
FAX:       (412) 249-4101
EMAIL:   www.beasensors.com
REV BY:
80.0246.04
SCALE:
DATE:
NONE
10/15/2007
PART NO:
SHEET
1 OF 1
JED
TUC
LO-LINX SUPERSCAN HARNESS
p/n: 70.5071
LO-LINX EAGLE HARNESS p/n: 20.5096
L
O
-L
IN
X
 BODY
G
U
ARD
H
A
RNE
SS
 p/n: 2
0
.5082
L
O
-LINX PO
W
E
H
A
RNE
SS
 p/n: 20
.5095
LO-LINX HOLD SWITCH HARNESS p/n: 20.5078
LO-LINX CONTROL
HARNESS p/n: 20.5097
HOLD OPEN
OFF
AUTO
RED
BLACK
WHITE
75.5137.
0
2
LO-LINX
SETUP
INCR.
FUNCT.
12-
24V
AC
/D
C
PWR
TO CTRL
ST
A
L
L
SAF
ET
Y
AC
T
IV
.
ST
ALL
 C
O
M
S
FTY
 /
 A
C
T COM
BEAM
TX
RX
SWITCH
GN
D
AU
T
O
HO
L
D
AUX
CO
M
N/
O
EAGLE
 1
EAGLE
 2
BOD
Y
-
GU
A
R
D
SENSORS
D
OOR
 M
T
D
SEN
SO
R
 1
D
OOR
 M
T
D
SEN
SO
R
 2
MTR
MO
T
O
R
S
T
ALL 1
STALL
S
T
ALL 2
RE
D
BLAC
K
WH
IT
E
BR
OW
N
BLU
E
GR
EE
N
GR
EEN
WH
IT
E
BL
AC
K
RED
EAGLE 2
GR
EE
N
WH
IT
E
BL
ACK
RE
D
EAGLE 1
RE
D
BLAC
K
WH
IT
E
BR
OW
N
BLU
E
GR
EE
N
E
M
P
T
Y
  
  
  
  
  
 1
IN
H
IB
IT
 G
N
D
 2
IN
H
IB
IT
 +
  
  
  
 3
N
.C
  
  
  
  
  
  
  
 4
N
.O
  
  
  
  
  
  
  
 5
C
O
M
  
  
  
  
  
  
  
 6
P
O
W
E
R
  
  
  
  
  
7
P
O
W
E
R
  
  
  
  
  
8
E
M
P
T
Y
  
  
  
  
  
 1
IN
H
IB
IT
 G
N
D
 2
IN
H
IB
IT
 +
  
  
  
 3
N
.C
  
  
  
  
  
  
  
 4
N
.O
  
  
  
  
  
  
  
 5
C
O
M
  
  
  
  
  
  
  
 6
P
O
W
E
R
  
  
  
  
  
7
P
O
W
E
R
  
  
  
  
  
8
RE
D
BLAC
K
WH
IT
E
G
R
EEN
RE
D
BLAC
K
WH
IT
E
G
R
EEN
DOOR MTD SENSOR
APPROACH SIDE
DOOR MTD SENSOR
SAFETY SIDE
E
M
P
T
Y
  
  
  
  
  
 1
IN
H
IB
IT
 G
N
D
 2
IN
H
IB
IT
 +
  
  
  
 3
N
.C
  
  
  
  
  
  
  
 4
N
.O
  
  
  
  
  
  
  
 5
C
O
M
  
  
  
  
  
  
  
 6
P
O
W
E
R
  
  
  
  
  
7
P
O
W
E
R
  
  
  
  
  
8
E
M
P
T
Y
  
  
  
  
  
 1
IN
H
IB
IT
 G
N
D
 2
IN
H
IB
IT
 +
  
  
  
 3
N
.C
  
  
  
  
  
  
  
 4
N
.O
  
  
  
  
  
  
  
 5
C
O
M
  
  
  
  
  
  
  
 6
P
O
W
E
R
  
  
  
  
  
7
P
O
W
E
R
  
  
  
  
  
8
RE
D
BLAC
K
WH
IT
E
G
R
EEN
RE
D
BLAC
K
WH
IT
E
G
R
EEN
DOOR MTD SENSOR
APPROACH SIDE
DOOR MTD SENSOR
SAFETY SIDE
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call B.E.A.,Inc. If you must wait for the following
workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an
incomplete solution. During EST 8am - 5pm call B.E.A., @ 800-523-2462. After 5pm EST all 866-249-7937 or 866-836-1863. After 5pm CST call 800-407-4545 or
888-308-8843. After 5pm MST or PST call 888-419-2564. Ensure compliance with current applicable standards. i.e. ANSI 156.10.
SEE NOTE #5
GREEN
BLUE
YELLOW
BROWN
WHITE
BESAM 300/400
(ETIK) CONTROL
7 NOT USED
8 NOT USED
9 NOT USED
10 COMMON
11 SAFETY
12 COMMON
13 ACTIVATION
14 COMMON
15 STALL
16 STALL COM.
17 STALL
18 STALL COM.
NOTES:
1. LO-LINX MOTOR HARNESS CONNECTION IS TIED IN PARALLEL TO EXISTING MOTOR LEADS OF 1 MOTOR ONLY. NO RESPECT TO POLARITY IS REQUIRED.
2. EXTERNAL SWITCHES (OR "B" SWITCHES) ARE REQUIRED IF INHIBIT DESIRED AT SWING SIDE SUPERSCANS, SWITCH OPENS UPON INHIBIT POINT.
3. THE KNOWING ACT SWITCH IS CONNECTED AT THE AUX INPUT AND CAN BE ANY DRY CONTACT DEVICE SUCH AS A PUSHPLATE, CARD READER, ETC.
THE AUX INPUT IS REQUIRED FOR ALL INITIAL ACTIVATION WHEN FUNCTION FA ON THE LO-LINX IS SET TO '01'.
4. THE SECOND BODYGUARD AND EAGLE ARE PRIMARILY USED IN DUAL-EGRESS APPLICATIONS. IF A SECOND BODYGUARD IS REQUIRED, USE A "Y" HARNESS (20.5083).
5. SET LO-LINX FUNCTION "FS" TO 01. ENSURE BODYGUARD RELAY VALUE IS SET TO 2.
LO-LINX MOTOR HARNESS p/n: 20.5076
SEE NOTE #4
SEE NOTE #4
BLACK
RED
24 V 
TRANSFORMER
SEE NOTE #1
LO-LIN X
GR EEN
WH IT E
YELLOW
B LUE
B R OWN
SWIN G
A C T .
C OM .
SA F .
ST A LL
ST A L  C OM .
BESAM  300
13
12
11
15, 17
16,18
BESAM   M /P
3
4
9
5
13
DOM
YELLOW
GREY
BLUE
PURPLE
GREY
GT 300/400
BLACK
RED
WHITE
WHITE
RED
GT M AG
6 BLACK
5 RED
4 WHITE
3 VIOLET
5 RED
HORTON 4190
2
3, 6, 8
4
10
3, 6, 8
HUNTER
ACT.
RTN
SAF. 1
SAF. 2
RTN
KM  K
GREEN
WHITE
RED
YELLOW
WHITE
STANLEY "L"
ORANGE YELLOW
RED
BLUE
YELLOW
STANLEY M /P
2
1, 8
7
7
1, 8
STANLEY 521
TB4-5
TB4-4
TB4-8
TB4-10
TB4-9
TORM AX TDA
2
1 ,3, 6, 8
8 & 9
7
1, 3, 6, 8
COM
N/
O
SEE NOTE #3
SEE NOTE
#2