SIZE:
DRAWN BY:
TITLE: MC-25 WITH ELECTRIC PANIC,
PUSHPLATE AUTOMATIC DOOR
APPLICATION
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA  15275
PHONE: (412) 249-4100
FAX:       (412) 249-4101
EMAIL:   www.beasensors.com
REV BY:
KJG
JDC
80.0142.02
SCALE:
DATE:
NONE
20 MARCH 2006
PART NO:
SHEET
1 OF 1
NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1.
2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
3) TRANSFORMER AND BRIDGE RECTIFIER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF
ELECTRIC PANIC.
4) MAGNETIC REED SWITCH MUST BE CLOSED WHILE DOOR IS OPEN.
5) SET MC-10 TIME DELAY FOR THE LENGTH OF TIME TO KEEP PANIC UNLOCKED ONCE CLOSED. IF PANIC CURRENT
LOAD IS GREATER THAN 500 mA, AN AUXILLARY RELAY MUST BE USED.  PLEASE CONTACT BEA TECHNICAL
SERVICES FOR MORE INFORMATION.
24 V 
TRANSFORMER
COM
N/O
PUSH TO
OPEN
BLACK
PURPLE
RED
GRAY
GRAY
ACTIVATE
COMMON
BRIDGE
RECTIFIER
~
~
+
-
+
-
BLACK
PURPLE
RED
PANIC
HARDWARE
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM