BEA 80.0011.02 Manual Do Utilizador

Página de 17
SIZE:
DRAWN BY:
TITLE: MC-25 WITH RECEIVERS, SEPARATE
POWER SUPPLY FOR MAGLOCK,
NIGHT MODE RELAY
A
NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS.
2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLTS).
100 ENTERPRISE DRIVE
PITTSBURGH, PA  15275
PHONE: (412) 249-4100
FAX:       (412) 249-4101
EMAIL:   www.beasensors.com
REV BY:
KJG
KJG
80.0020.02
SCALE:
DATE:
NONE
18 MAY 2005
PART NO:
SHEET
1 OF 1
COM
DOOR
CONTROL
ACT
RED COMMON
BLACK N/O
24 V 
TRANSFORMER
COMPUTER SYSTEM
POWER SUPPLY
MAGLOCK
WHITE
GREEN
BLACK
RED
POWER 24 VAC
POWER 24 VAC
N / O
COMMON
WHITE
GREEN
BLACK
RED
POWER 24 VAC
POWER 24 VAC
N / O
COMMON
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM