Bosch Appliances Video Game Controller D9412GV2 Manual Do Utilizador

Página de 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 13 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
Point/User Flag 
Default: 
Yes 
Selection: 
Yes or No 
Yes 
The control panel sends a flag with 
each report telling the D6500 or 
D6600 to convert point numbers and 
User ID numbers to COMEX format. 
Refer to Table 7 anTable 8 for 
conversion information. When this 
parameter is programmed Yes
points and User ID numbers are 
converted, regardless of the 
programming of the D6500 or D6600 
Receiver for output to the computer 
system. Refer to Appendix C in the 
Conettix D6600/D6100 
Receiver/Gateway Computer 
Interface Manual
 (P/N: 4998122703). 
No 
The control panel does not send the 
flag. The D6500 or D6600 outputs 
point numbers as 001 to 247 (rather 
than 100 to 732) and User ID 
numbers as 000 to 249 (rather than 
000 to F08), as indicated in Table 7 
and Table 8
This program item determines how point and User ID 
numbers are presented at the D6500 or D6600 
display, printer, and computer RS-232 output. 
When Modem Format is Yes, the control panel 
sends expanded Bosch Modem IIIa
2
 Communication 
Format reports to the D6500 or D6600. If your central 
station data files are not set up for point and User ID 
number reporting, you can use this program item to 
convert these numbers to COMEX Reports.  
When Modem Format is Yes, the control panel 
sends expanded Bosch Modem IIIa
Communication 
Format Reports to the receiver. Point/User Flag 
affects Bosch Modem IIIa
Communication Format 
data as shown in Table 7. The Bosch Security 
Systems, Inc. D6500 or D6600 Receiver adds the 
leading zero in the User ID number with Point/User 
Flag
 programmed No. 
 
Table 7:  Modem IIIa
2
 Communication Format 
Data - User ID Numbers 
 
Point/User Flag 
NO 
Point/User Flag 
YES 
000 
000 
001 to 005 
001 to 005 
006 to 013 
601 to 608 
014 to 021 
701 to 708 
022 to 029 
801 to 808 
030 to 037 
B01 to B08 
038 to 045 
C01 to C08 
046 to 053 
D01 to D08 
054 to 061 
E01 to E08 
062 to 069 
F01 to F08 
070 to 249 
000 
 
 
 
Table 8:  Modem IIIa
2
 Communication Format 
Data – Point Numbers 
 
Point/User Flag 
NO 
Point/User Flag 
YES 
001 to 008 
100 to 800 
009 to 024 
101 to 116 
025 to 040 
201 to 216 
041 to 056 
301 to 316 
057 to 072 
401 to 416 
073 to 088 
501 to 516 
089 to 104 
601 to 616 
105 to 120 
701 to 716 
121 to 136 
801 to 816 
153 to 168 
217 to 232 
169 to 184 
317 to 332 
185 to 200 
417 to 432 
201 to 216 
517 to 532 
217 to 232 
617 to 632 
233 – 247 
717 to 731