Bags and Gloves E-9220T Manual Do Utilizador

Página de 124
54
www.gateway.com
Chapter 4: Installing Components
Replacing a power supply module
If your server uses the optional hot-swappable, redundant power supplies and one of the 
two power supplies fails, the other power supply module supports the server while you 
replace the failed module. You do not need to turn off the server or disconnect peripheral 
devices to replace a failed power supply module.
To replace a power supply module:
1
If you only have one power supply module, turn off your server.
2
If you have two power supply modules, examine the LED indicators on the back of 
each power supply module to identify the failed module. The power supply module 
has failed if the orange (right) LED indicator is on.
3
Unplug the power cord from the failed power supply module.
Warning 
The power supply modules in this server contain no user-serviceable 
parts. Only a qualified computer technician should service the power 
supply modules.
Your server comes with 3-wire AC power cords fitted with the correct 
plug style for your region. If this plug does not match the connector 
on your surge protector, UPS, or wall outlet, do not attempt to modify 
the plug in any way. Use a UPS or wall outlet that is appropriate for 
the supplied AC power cords.
Power supply fault LED
Power on LED
Power connector
Power supply latch
Power supply handle