SAFETY
ELECTRICAL
This  equipment  must  be  grounded. 
Verify that any existing electrical out-
let and circuit you intend to plug into 
is  actually  grounded.  If  it  is  not,  it 
will be necessary to run a separate 12 
A.W.G.  copper  grounding  wire  from 
the outlet to a known ground. Under 
no  circumstances  should  the  ground-
ing  pin  from  any  three-pronged  plug 
be  removed  or  serious  injury  may 
occur.
110V Operation
When it is necessary to use an extension cord, use the 
following guidelines:
 
•  Use cords rated for standard service.
 
•  Never exceed a length of 100 feet.
 
•  Use cords with 14 ga. wire or bigger.
 
•  Insure cord has a ground wire and pin.
 
•  Do not use cords in need of repair.
Extension Cords
Grounding
This machine must be grounded
! The electrical cord sup-
plied with the Model M1051 comes with a grounding pin. 
Do not remove it (see
 Figure 2). If your outlet does not 
accommodate a ground pin, have it replaced by a quali-
fied electrician or have an appropriate adapter installed. 
Note: When using an adapter, the adapter must be 
grounded.
The SHOP FOX
®
 M1051 operates at 110 volts. The motor 
supplied with this machine is rated at 
1
3
 HP. When 
choosing an outlet for this machine, consider using one 
with a 15 amp circuit breaker or fuse. Keep in mind that 
a circuit being used by other machines or tools at the 
same time will add to the total load being applied to the 
circuit. Add up the load ratings of all machines on the 
circuit. If this number exceeds the rating of the circuit 
breaker or fuse, use a different circuit.
Figure 2. Never remove the grounding 
pin!