6. Position the oven broil burner against the roof of the oven 
cavity and attach with screw.
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove the burner caps.
3. Using a Phillips screwdriver, remove the burner base. 
4. Apply masking tape to the end of a 
⁹⁄₃₂" (7 mm) nut driver to 
help hold the Natural gas orifice spud in the nut driver while 
changing it. Press nut driver down onto the Natural gas orifice 
spud and remove by turning it counterclockwise and lifting 
out. Set Natural gas orifice spud aside. 
Use the following chart for correct LP gas orifice spud for each 
burner. Refer to the model/serial rating plate on the lower right 
side of the front frame for proper sizing of LP gas orifice spuds 
for each burner location.
LP Gas Orifice Spud Chart
5. Replace the Natural gas orifice spud with the correct LP gas 
orifice spud. See the “LP Gas Orifice Spud Chart.”
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place Natural gas orifice spuds in plastic parts bag for future 
use and keep with package containing literature.
10. Replace burner grates.
11. Reinstall storage drawer. See the “Replace Oven Racks and 
Storage Drawer” section for instructions.
12. Reinstall oven door. See the “Oven Door” section of the Use 
and Care Guide.
13. Complete installation. See “Make Gas Connection” and 
“Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important. 
The small inner cone should have a very distinct blue flame 
¼" to ½" long. The outer cone is not as distinct as the inner 
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the “Lo” setting for 
each cooktop burner.
A. Oven broil burner orifice hood
B. Oven broil burner
C. Oven broil burner locator pin
D. Oven broil burner locator hole
A. Burner cap
B. Gas tube opening
C. Burner base screws
D. Burner base
A
B
C
D
A
B
C
D
A. Natural gas orifice spud
Burner Rating
Color
Number 
4,000 BTU
Blue
64L
9,100 BTU
Clear
91L
10,500 BTU
Green
97L
14,000 BTU
Red
114L
A