Whirlpool GW399LXUQ Guia De Configuração Rápida

Página de 40
9
4. Drill two 
¹⁄₈" (3 mm) holes that correspond to the bracket 
holes of the determined mounting method. See the following 
illustrations.
5. Using the Phillips screwdriver, mount anti-tip bracket to the 
wall or floor with the two #12 x 1
⁵⁄₈" screws provided.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in the following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and an adjustable wrench to 
attach the flexible connector to the adapters. Check that 
connector is not kinked. 
4. Gas supply pipe must not be more than 10" (25.4 cm) above 
the floor.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. If bubbles appear, a 
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from package 
containing parts. Align recess in burner caps with pins in 
burner base. Burner caps should be level when properly 
positioned. If burner caps are not properly positioned, 
surface burners will not light. Place burner grates over 
burners and caps.
Floor Mounting
Wall Mounting
A. #12 x 1
⁵⁄₈
" screws
B. Anti-tip bracket
A. #12 x 1
⁵⁄₈
" screws
B. Anti-tip bracket
A
B
A
B
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
E. 10" (25.4 cm) max. 
straight pipe
A. Closed valve
B. Open valve
A
B
C
D
E
F
G
H
Adaptor
A
B
C
D
E
A