White Rodgers 1F98EZ-1621 Emerson Blue Wireless Easy Install Thermostat System Instrução De Instalação

Página de 12
4
**T
o use the HV
A
C
 transformer to power humidification/dehumidification switch HM/DHM 
switches to “SYS
” position:

Connect humidifier to HM

Connect dehumidifier to DHM
If humidifier or dehumidifier has a separate transformer switch HM or DHM switch to “DRY” position
:

Connect humidifier to HM and HM
2 (o
r)

Connect dehumidifier to DHM and DHM
2
* For two transformer system, cut and tape off one transformer
. If 
transformer safety circuits are only in one of the systems, remove 
the transformer of the system with NO safety circuits. If required, 
replace remaining transformer with a 
75
 V
A
 Class II transformer
. After 
disconnecting 
one transformer
, the two commons must be jumpered 
together
.
DHM2 DHM
HM2 HM
L
SYSTEM
W
/E
W
2
Y
Y
2
G
O
/B
POWER
RC
Status/Fault
7-Segment LED
LED On/Off
Return Air Duct
Sensor Socket
Connect 
**HM Switch
**DHM Switch
Outdoor Condenser 
(A/C or Heat Pump)
Y
Y2
O/B
C
(if Heat Pump)
DHM
DHM
2
HM
2
W/E
W
2
Y
Y
2
G
O/B
L
HM
Indoor Air Handler/Furnace Connection
s
Heat Stage 
1 - Indoor Unit or Furnace (Conventional Gas, Oil, Elec) or HP
 1 
Stage Aux/Em
Heat Stage 
- Indoor Unit or Furnace (Conventional Gas, Oil, Elec) or HP 
2 Stage Aux/Em
Stage 
1 - Outdoor Condenser (Conventional or HP
)
Stage 
2 - Outdoor Condenser (
Conventional or HP) 
Fan Relay
Changeover Relay Heat Pump
Comfort Alert Connection
R
C
24
 VAC Transformer Hot
24 
VAC Transformer Neutral
Dehumidification Relay / Connection
Dehumidification Relay / Connection (for dry contacts)
Humidification Relay / Connection
Humidification Relay / Connection (for dry contacts)
Return Air Sensor (RAS) Required 
W/E
W
2
Y
Y
2
G
O/B
L
HM
HM2
DHM
SYS
DRY
SYS
DHM
2
RC
RH
R
C
*HVAC Transformer
24
 VAC
HO
T
NEUTRAL
120
 VAC
DRY
Connect Push
Button Switch
LED Push
Button Switch
R and C
from HVAC
Terminal Strip
or System 
Transformer
Status LED
EQUIPMENT CONTROL WIRING TO HVAC EQUIPMENT