Maintenance
 
 
WARNING: Turn off the electrical power 
supply, the manual gas control valve, and 
the manual water control valve before 
servicing. 
 
The unit should be checked once a year or as 
necessary by a certified and trained technician. If 
repairs are needed, the repairs should be done by 
a certified and trained technician. 
The following systems and parts should be 
checked at least once a year: 
1. Venting systems 
2. Burners 
3.  Manual operation of the pressure relief valve to 
ensure correct operation. 
4.  Periodic cleaning of the water filter, refer to 
figure below.  
5.  Heat exchanger. Remove the thermistor and 
check for a mineral coating . A mineral coating 
on the thermistor requires flushing the heat 
exchanger with a descaling solution. Scale 
build up will void your warranty and shorten the 
life of your water heater. 
 
 
 
 
Troubleshooting 
 
Water Isn’t Hot Enough 
 
The T-K1S can burn gas at a maximum input rate 
of 190,000 BTUH.  This puts a limit on the possible 
output temperature and flow capabilities (See flow 
chart on the last page of this manual).  If the water 
doesn’t seem hot enough, compare the flow and 
temperature that is being attained to the T-K1S 
flow vs. temperature chart.  If the unit is not 
performing according to the chart, first check that 
the gas supply line is sized properly, and that the 
gas pressure is within the required range.  If the 
gas line is okay, check the plumbing for mixing 
valves, thermostatic valves, scald protection, 
single handled valves or crossed connections.  If 
the unit is performing in accordance with the flow 
chart, then it may be undersized for the 
application.  If the unit is performing according to 
the chart, the output temperature can be adjusted 
using the T-K1S. 
  
It Takes Too Long to Get Hot Water 
 
The T-K1S takes three seconds to ignite, and 
three more to get up to temperature.  The rest of 
the time needed for hot water to get to a fixture is 
due to the length of piping between the water 
heater and the fixture.  If the unit seems to be 
taking longer than six seconds to initiate, check the 
filter and flow sensor for any debris or damage. 
 
The T-K1S Will Not Initiate 
 
First check the flow rate through the unit.  If the 
flow is not 0.75 GPM or greater, the unit will not 
initiate.  Check the filter and the flow sensor for 
any debris or damage. 
Press the lower green button on the GFCI inside 
the unit.  If the red light above it does not come on, 
then there is a problem with the electrical supply to 
the unit.  If that light does come on, hit the green 
reset button above the light, and look for the green 
light on the circuit plate at the top left of the unit.  If 
this light is not lit, there is a problem with the 
electrical connection between the GFCI and the 
circuit plate. Contact Takagi Industrial Company 
for instructions.