2. Using a pipe wrench to tighten, connect the gas supply to the 
range.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and G in following illustration). 
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 
¹⁵⁄₁₆" combination wrench and pliers to attach the 
flexible connector to the adapters. Check that connector is 
not kinked.   
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the 
“on” position.
2. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
4. Remove cooktop burner caps and grates from parts 
package. Align notches in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burner grates over burners and caps.
5. Plug into a grounded 3 prong outlet.
Check Operation
Electronic Ignition System
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of 
standing pilots. When the cooktop control knob is turned to the 
“LITE” position, the system creates a spark to light the burner. 
This sparking continues, as long as the control knob is turned to 
“LITE.”
When the oven control is turned to the desired setting, sparking 
occurs and ignites the gas.
A. Gas pressure regulator
B. 90° elbow (must have 
½" male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
F. Manual gas shutoff valve
G. ½" or ¾" gas pipe
H. Nipple
I. Union
J. 90° elbow 
A. Gas pressure regulator
B. Use pipe-joint compound
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound
H. Adapter
A. Gas pressure regulator shutoff valve
A
B
C
D
E
F
G
H
I
J
A
B
C
D
E
F
G
H
ON
A
A. Closed valve
B. Open valve
A. Burner base
B. Burner cap
C. Burner grate
A
A
B
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.