Whirlpool SF216LXSQ Guia De Configuração Rápida

Página de 32
9
3. Use a combination wrench and pliers to attach the flexible 
connector to the adapters. Check that connector is not 
kinked. 
Complete Connection
1. Locate gas pressure regulator in the back of the range.
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the 
“ON” position.
IMPORTANT: The factory default setting is the “ON” position. If 
the range does not work, verify that the valve is in the “ON” 
position.
3. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
5. Remove cooktop burner caps and grates from parts 
package. Align notches in burner caps with pins in burner 
base. Burner caps should be level when properly positioned. 
If burner caps are not properly positioned, surface burners 
will not light. Place burners, burner caps and grates on the 
cooktop.
6. Plug into a grounded 3 prong outlet.
A. Pressure regulator 
connection fitting
B. Use pipe-joint compound.
C. Adapter
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G. Manual shutoff valve
H. ½" or ¾" gas pipe
A. Gas pressure regulator
A.
On
 position
B.
Off
 position
C
E
G
H
A
D
F
B
A
A
B
A. Closed valve
B. Open valve
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING