The water cooling pump WL 1001 consists of the following components:
1 storage tank (1.5 liter capacity)
1 thermostat
1 radiator
1 thermostat
1 radiator
1 electric motor with PROCON pump
1 ventilator
1 ventilator
1 fail-safe water turbine flow rate monitor *)
1 protective housing
1 connecting cable 10 m / 32 ft long (optionally up to 100 m / 320 ft max.)
1 protective housing
1 connecting cable 10 m / 32 ft long (optionally up to 100 m / 320 ft max.)
*) the 230 V version is equipped with a fail-safe water turbine flow rate monitor;
the 110 V version is equipped with a water flow switch only
Description
Technical Data
Power supply
230 V / 50 Hz / 0.18 kVA
or
115 V / 60 Hz / 0.18 kVA
Max. pressure
approx. 6.0 bar (at 22°C)
Flow rate
approx. 5.1 l /min at 4 bar outlet pressure
Dimensions
295 x 330 x 315 mm / 11.6 x 13 x 12.4 (W x D x H)
Weight
24 kg / 53 lbs (filled ; incl. 10 m / 32 ft cable)
Finish
All parts likely to be affected by the cooling water are
made of stainless steel, or of a non-corroding alloy
Water connector
½-inch water connection (optionally fast access connectors)