Toyotomi Laser 56 Instrução De Instalação

Página de 32
SECTION A:
SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W 
×H ×D):
(Includes drip tray)
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
Laser 56
93% (1)
High - 22,000 BTU/h   (6,453 Watts)
Med - 15,000 BTU/h   (4,400 Watts)
Low -
8,000 BTU/h   (2,347 Watts)
High - 0.165 gal/h (0.625 L/h)
Med - 0.113 gal/h (0.428 L/h)
Low - 0.060 gal/h (0.227 L/h)
External tank (2)
ASTM No.1-K Kerosene Only
24-3/8“ 
× 26-3/4“ × 16“
(62.0 
× 68.0 × 40.5 cm)
60 lbs. (27 kg) Empty
2-3/4“ ~ 3“ diameter
(7.0 - 7.5 cm)
10 ft. (3 m), 3 bends or less
120 Volts AC, 60 Hz
Preheat - 275W
Burning - 60W
920 square feet (0
°F)
1100 square feet (20
°F)
(1)
(2)
(3)
Heat and vaporized water are produced by the combustion process of this kerosene heater. This rating 
does not take into account heat loss due to condensation of water vapor.
External tank to be purchased from local suppliers.
0
° F Heat Load = 24 BTU/ft
2
/hr
20
° F Heat Load = 20 BTU/ft
2
/hr
Room size for which this heater is suitable will vary depending on outside temperature, house 
insulation, window size, and other factors.
2