Klark Teknik U.S.A. Air Compressor DN540 Manual Do Utilizador

Página de 54
DN540
Operator Manual
17
 
Chapter 5: Rear Panel
The rear panel of the DN540 (shown below) has a mains input section and four channel 
connector sections.
Note: Although the rear panel of the DN540 has cutouts for two solo bus connectors, 
these are unused on this unit and are therefore blanked off.
Mains input
The mains input section has a mains 
IEC socket, below which is a fuse 
drawer.  Printed just to the right are 
the mains supply voltage and fuse 
details.
The mains input is an auto voltage 
sensing, switch mode power supply 
that operates where normal mains 
voltage is in the range 100V AC to 
240V AC.
The fuse drawer houses the mains fuse 
at the rear of a two-compartment drawer.  The front compartment provides room for a 
spare.  Always replace the mains fuse with one of the same type of and rating, as 
printed to the right of the fuse drawer.
Channel connector section
There are four similar channel sections on the 
rear of the DN540.  Each section comprises a 
male (output) and a female (input) XLR chassis 
connector, and a 1/4” TRS connector.  These are 
for connecting to external line level signals, such 
as a mixing console’s insert connections.
Mains input
Four channels
Mains IEC socket
Fuse drawer