● Timeout timer settings   
 
During KNS operations, control data signals are transmitted using the network. 
Consequently, if normal network operations are disabled for any reason, control of the 
transceiver will also be disabled. Use the following menu to set the functions to stop 
transmitting automatically after a fixed period if control should be disabled while 
transmitting.   
 
Menu No.   
Function   
Setting range 
(Default)   
6-02   
Maximum continuous transmit time (time- 
out timer)   
Off, 3, 5, 10, 
20, 30 [min] 
(Off)   
 
 
● Prohibit transmission setting   
 
If using the host station as a receive-only station, set to transmission inhibited. Make 
the settings using the following menu.   
 
Menu No.   
Function   
Setting range 
(Default)   
6-03   
Transmit inhibit   
Off, On 
(Off)   
 
 
● Allocating the DATA SEND function to PF keys   
 
Set the DATA SEND function to the PF keys to test the transmission of audio input from 
the ACC2 connector or USB connector. In this example, the [PF A] key has been set.   
 
Menu No.   
Function   
Set value   
0-15   
Assignment of the programmable function 
to [PF A]   
DATA SEND   
 
Using the PF key, which has been set to the DATA SEND function, enables switching 
between transmit and receive modes for audio input from the ACC2 connector or USB 
connector.