Maretron TLM100 Manual Do Utilizador

Página de 21
 
 
®
®
1” (2.54cm) clearance 
between focus tube and 
tank bottom 
TLM100 Interface Component 
Threaded Tank Fitting 
Threaded Focus Tube 
TLM100 Gasket 
TLM100 Sensor Component 
Mounting Screws 
Figure 5 – Mounting TLM100 with Focus Tube on Threaded Tank Fitting 
 
 
2.4.1.6  Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and 
Airlock 
 
Installation of the TLM100 on a tank with a 1.25” BSP or 1.5” NPT threaded tank fitting with an 
airlock is identical to installation with a focus tube, except that the trimming step is eliminated. 
Please refer to Section 2.4.1.5 for details of the mounting procedure. 
 
2.4.2  Mounting the TLM100 Interface Component 
The actual mounting of the TLM100 interface component is not critical and the unit can be 
mounted in any orientation. The TLM100, NMEA 2000
®
 connector, and cable are all 
waterproof (rated IP67 – protected against temporary immersion in water) so you can mount 
the unit virtually anywhere. Once you have located a suitable mounting location, you can 
secure the TLM100 interface component by placing wire ties with screw eyes on the attached 
cables next to the TLM100 interface component. Do not use threadlocking compounds 
containing methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of 
the plastic enclosure. 
 
 
 
 
Revision 1.3 
 
Page 9