Enviro HORIZONTAL VENT KIT 50-1235 Folheto

Página de 2
MANUFACTURED BY:
SHERWOOD INDUSTRIES LTD. 
6782 OLDFIELD RD.  SAANICHTON, BC, CANADA  V8M 2A3
www.envirofi re.biz
April 13, 2005
C-10857
Part Number
Option
50-1235
Horizontal Vent Kit  
Flue Pipe Adaptor
Wall Framing
Wall Thimble
Fire Stop
Exhaust 4" Flex Pipe
Combusion Air 6 5/8" Flex Pipe
Wire Spacers
Horizontal Vent Termination
9.   Install the fl ex pipe assembly through the wall thimble, ensure that this 
portion of pipe slides through the outside wall far enough to connect onto 
the vent termination cap.
10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) 
by 5” (12.5 cm) fl ue collar adaptor previously installed into the fi replace 
fl ue outlet.  Slide the Ø4” (10 cm) fl ex vent over the fl ue collar and secure 
with three (3) sheet metal screws evenly spaced.
11. Place a bead of high temperature silicone on the intake collar of the 
fi replace, slide the Ø6⅝” (16.25 cm) fl ex intake liner over the collar, 
secure the fl ex liner with three (3) sheet metal screws evenly spaced.
12. On the outside of the 
exterior wall, apply a 
bead of Mill-Pac Black 
sealant to the Ø 4” (10 
cm) pipe of the vent 
terminal.  Slide the 
fl ex liner onto the vent 
terminal and secure with 
three (3) sheet metal 
screws evenly spaced.
13. Place a bead of high 
temperature silicone on 
the intake collar of the 
vent terminal, slide the 
Ø6⅝” (16.25 cm) fl ex 
intake liner over the 
collar, secure the fl ex liner 
with three (3) sheet metal 
screws evenly spaced.
14. Attach the vent terminal 
to the outside of the 
house using four (4) 
wood screws provided. 
15. Light the appliance and 
ensure proper operation.
Figure 3
Figure 3