Fujitsu MB96300 Manual Do Utilizador

Página de 36
SK-96370-144PMC-GDC User Guide 
Chapter 3 Jumpers and Switches 
FMEMCU-UG-960014-10 
- 20 - 
© Fujitsu Microelectronics Europe GmbH 
3.9  LIN / UART 
There are two identical circuit blocks for LIN or RS232 connections. Each of the two D-Sub 
connectors can be configured as LIN or RS232 interface. DTS or RTS can be selected as 
reset source, and RTS and CTS can be connected by a jumper, since some terminals and 
Flash programming tools need this connection. Pin 1 (Vs) of X5 and X9 can be connected to 
the voltage input of the board by jumpers in order to supply the LIN bus. 
 
3.9.1  LIN-UART 0 (JP: 19, 21, 23, 25, 27, 28, 29, 31) 
Jumper 
Setting 
Description 
1-2 
SIN0 is connected to RS232 transceiver 
JP21 
(RXD) 
2-3 
SIN0 is connected to LIN transceiver 
1-2 
SOT0 is connected to RS232 transceiver 
JP25 
(TXD) 
2-3 
SOT0 is connected to LIN transceiver 
1-2 
X5 pin 2 is connected to RS232 transceiver  
JP27 
(RS232/LIN) 
2-3 
X5 pin 2 is connected to LIN transceiver  
Closed 
RTS and CTS of X5 are connected 
JP19 
(RTS-CTS) 
Open 
RTS and CTS of X5 are not connected 
1-2 
DTR signal (pin 6 of X5) is used as reset source 
JP23 
(DTR/RTS) 
2-3 
RTS signal (pin 7 of X5) is used as reset source 
Closed 
LIN transceiver is enabled 
JP29 
(LIN enable) 
Open 
LIN transceiver is disabled 
Closed 
LIN-UART0 is LIN Master 
JP31 
(LIN master) 
Open 
LIN-UART0 is LIN Slave 
Closed 
LIN bus (X5 pin 1) is powered by the board 
JP28 
(LIN Vbat) 
Open 
LIN bus (X5 pin 1) is not powered by the board 
Table 3-7: UART0 Settings