LOCATING THE HEATER
 WARNING
THERE IS A RISK IN USING FUEL BURNING APPLIANCES SUCH AS 
GAS  WATER  HEATERS  IN  ROOMS,  GARAGES  OR  OTHER AREAS 
WHERE  GASOLINE,  OTHER  FLAMMABLE  LIQUIDS  OR  ENGINE 
DRIVEN EQUIPMENT OR VEHICLES ARE STORED, OPERATED OR 
REPAIRED. FLAMMABLE VAPORS ARE HEAVY AND TRAVEL ALONG 
THE FLOOR AND MAY BE IGNITED BY THE HEATER’S IGNITER OR 
MAIN BURNER FLAMES CAUSING FIRE OR EXPLOSION. SOME LOCAL 
CODES PERMIT OPERATION OF GAS APPLIANCES IF INSTALLED 18 
INCHES (46 cm) OR MORE ABOVE THE FLOOR. THIS MAY REDUCE 
THE RISK IF LOCATION IN SUCH AN AREA CANNOT BE AVOIDED.
THE HEATER SHALL BE LOCATED OR PROTECTED SO IT IS NOT 
SUBJECT TO PHYSICAL DAMAGE BY A MOVING VEHICLE.
DO NOT LOCATE THE HEATER WHERE NOISE FROM THE EXHAUST 
OR INTAKE WILL BE OBJECTIONABLE. THIS INCLUDES LOCATIONS 
CLOSE  TO  OR ACROSS  FROM  WINDOWS AND  DOORS. AVOID 
ANCHORING THE VENT AND INTAKE PIPES DIRECTLY TO FRAMED 
WALLS, FLOORS OF CEILINGS UNLESS RUBBER ISOLATION PIPE 
HANGERS ARE  USED.  THIS  PREVENTS ANY  VIBRATIONS  FROM 
BEING TRANSMITTED INTO THE LIVING SPACES.
 WARNING
FLAMMABLE  ITEMS,  PRESSURIZED  CONTAINERS  OR ANY  OTHER 
POTENTIAL FIRE HAZARDOUS ARTICLES MUST NEVER BE PLACED ON 
OR ADJACENT TO THE HEATER. OPEN CONTAINERS OF FLAMMABLE 
MATERIAL SHOULD NOT BE STORED OR USED IN THE SAME ROOM 
WITH THE HEATER.
When installing the heater, consideration must be given to proper location. 
Location selected should be as close to the intake and exhaust termination 
points as practicable, with adequate air supply and as centralized with the 
piping system as possible.
THE HEATER MUST NOT BE LOCATED IN AN AREA WHERE IT WILL BE 
SUBJECT TO FREEZING.
LOCATE IT NEAR A FLOOR DRAIN. THE HEATER SHOULD BE LOCATED 
IN AN AREA WHERE LEAKAGE FROM THE HEATER OR CONNECTIONS 
WILL NOT RESULT IN DAMAGE TO THE ADJACENT AREA OR TO LOWER 
FLOORS OF THE STRUCTURE. 
When such locations cannot be avoided, it is recommended that a suitable 
drain pan, adequately drained, be installed under the appliance.
Water  heater  life  depends  upon  water  quality,  water  pressure  and  the 
environment  in  which  the  water  heater  is  installed.  Water  heaters  are 
sometimes  installed  in  locations  where  leakage  may  result  in  property 
damage,  even  with  the  use  of  a  drain  pan  piped  to  a  drain.  However, 
unanticipated damage can be reduced or prevented by a leak detector or 
water  shut-off  device  used  in  conjunction  with  a  piped  drain  pan. These 
devices are available from some plumbing supply wholesalers and retailers, 
and detect and react to leakage in various ways:
•  Sensors mounted in the drain pan that trigger an alarm or turn off the 
incoming water to the water heater when leakage is detected.
•  Sensors mounted in the drain pan that turn off the water supply to the entire 
home when water is detected in the drain pan.
•  Water supply shut-off devices that activate based on the water pressure 
differential between the cold water and hot water pipes connected to the 
water heater.
•  Devices that will turn off the gas supply to a gas water heater while at the 
same time shutting off its water supply.
 WARNING
THIS WATER HEATER IS A CONDENSING UNIT AND REQUIRES A DRAIN 
TO BE LOCATED IN CLOSE PROXIMITY TO ALLOW THE CONDENSATE 
TO DRAIN  SAFELY. THE  CONDENSATE  DRAINS  FROM THE  UNIT AT 
THE EXHAUST ELBOW LOCATED AT THE BOTTOM OF THE UNIT. NOTE: 
IT IS IMPORTANT THAT THE CONDENSATE HOSE NOT BE ELEVATED 
ABOVE THE EXHAUST ELBOW (SEE FIGURE 3). THE CONDENSATE 
BUILD-UP WILL BLOCK THE EXHAUST OUTLET, WHICH WILL CAUSE 
IMPROPER OPERATION.
                       
FIGURE 3.
 WARNING
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. 
IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT 
THE APPLIANCE AND  TO  REPLACE ANY  PART  OF  THE  CONTROL 
SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
CLEARANCES
These heaters are approved for installation on combustible flooring in an 
alcove when the minimum clearances from any combustion construction are 
followed as indicated in Figure 4.
In all installations the minimum combustible clearances from any vent piping 
shall be 0". Vent piping passing through a combustible wall or ceiling must 
be a continuous run (no joints).
A service clearance of 24" (61 cm) should be maintained from serviceable 
parts such as relief valves, flue baffles, flue damper devices, thermostats, 
cleanout openings or drain valves.
Always disconnect electrical power before servicing the unit.
FIGURE 4.
*ILLUSTRATION OF MINIMUM COMBUSTIBLE CLEARANCES IN AN     
 ALCOVE.