Avaya Sun Fire V880 Instrução De Instalação

Página de 208
Tools
Issue 2.0 June 2004
169
Probing disk drives
This test checks all disk drives.
Symptom - The internal disk drives are reporting errors.
Solution - To check the status of the disk drives:
1. Enter:
/usr/sbin/shutdown -y -i0 -g0
This shuts down the system.
2. At the ok prompt, enter the following commands:
setenv auto-boot? false
reset-all
The system resets. 
3. Enter:
probe-scsi
The program displays a message that is similar to the following:
Note:
Note:
The actual response depends on the number of disk drives that are installed 
in the system. This example shows six disk drives and the disk drive 
backplane.
4. Fix any obvious errors, such as disconnected backplane cables or disk drives not 
completely inserted.
LiD HA LUN
--- Port WWN ---
-----Disk description -----
0
0
0
21000004cf72f08f
SEAGATE ST373405FSUN3660438
1
1
0
21000004cf721553
SEAGATE ST373405FSUN3660438
2
2
0
21000004cf7213ea
SEAGATE ST373405FSUN3660438
6
6
0
508002000016b5b1
SUNW
SUNWGS INT FCBPL9224
3
3
0
21000004cf72114b
SEAGATE ST373405FSUN3660438
4
4
0
21000004cf7211ae
SEAGATE ST373405FSUN3660438
5
5
0
21000004cf7214a3
SEAGATE ST373405FSUN3660438