Avaya Sun Fire V880 Instrução De Instalação

Página de 208
Installation
28 Avaya CMS Sun Fire V880 Computer Hardware Installation, Maintenance, and Troubleshooting
Setting up power
To set up the AC power:
1. Locate the key switch, insert the key, and turn the key switch to the Forced Off position. 
See the following figure.
2. Connect the IEC 320 end of each power cord to the AC connector of each power 
supply.
For installations outside of the United States and Canada, obtain three power cords for 
your local configuration.
3. Route the power cord through the strain-relief tie-wrap loop located to the right of the 
supply. Tighten the tie-wrap to secure the connection.
4. Plug the power cords from the computer using one of the following schemes:
Connect the computer using two (2) 2KVA Uninterruptible Power Supplies (UPS) (or 
equivalent), each powered by a nonswitched, dedicated, 15-amp circuit. Connect 
two of the power supplies to one UPS, and the third power supply to the second 
UPS. The monitor and external peripherals can also be connected to the second 
UPS.
If not using a UPS, each power supply should be connected to a nonswitched, 
dedicated, 15-amp circuit. The monitor and external peripherals should be 
connected to a separate circuit.
!
Important:
!
Important:
Important:
Do not turn on power at this time.