World Marketing of America KOZY-WORLD KWN109 Manual Do Utilizador

Página de 14
1 4
TROUBLESHOOTING
Note  :        All          troubleshooting
items    are    listed    in  order    of
operation.
    WARNING:  Only    a   qualified
service  person  should  service and
repair  heater.
   CAUTION:   Never  use  a  wire,
needle,  or  similar  object   to  clean
ODS/pilot.    This    can    damage
ODS/pilot  unit.
OBSERVED  PROBLEM
When  ignitor  button  is  pressed  and
control knob is pressed in and turned to
the PILOT position, there  is  no  spark
at  ODS/pilot.
When  ignitor  button  is  pressed and
control knob is press in and turned to
the PILOT position, there  is  a spark
at  ODS/pilot  but  no ignition.
ODS/pilot    lights   but flame   goes out
when   control   knob is released.
POSSIBLE  CAUSE
1.   Ignitor electrode is positioned
      wrong.
2.   Ignitor electrode is broken.
3.   Ignitor electrode is not connected
      to  ignitor cable.
4.   Ignitor cable  is pinched  or wet.
5.   Broken ignitor cable.
6.   Bad piezo ignitor.
1.   Gas supply turned off or equipment
      shutoff  valve  is closed.
2.   Control  knob  not fully  pressed  in
      while  pressing  ignitor  button.
3.   Air  in  gas  lines  when  installed.
4.   ODS/pilot  is  clogged.
5.   Gas  regulator  setting is not correct.
6.   Control  knob  not in  PILOT  position.
1.   Control knob is not fully pressed in.
2.   Control  knob  is not  pressed  in
       long enough.
3.   Equipment  shutoff  valve  is not
       fully open.
4.   Thermocouple   connection   is
       loose at  control  valve.
5    Pilot   flame  is  not   touching
      thermocouple,    This    allows
       thermocouple  to cool,  causing
       pilot   flame   to   go   out.  This
      problem  could  be  caused  by
       one  or  both  of  the  following:
      A)    Low   gas  pressure
      B)   Dirty    or   partially  clogged
            ODS/ pilot
6.   Thermocouple   damaged.
7.   Control valve   damaged.
REMEDY
1.   Replace ignitor.
2.   Replace ignitor.
3.   Reconnect ignitor cable.
4.   Free  ignitor  cable  if  pinched  by
       any       metal     or     tubing.    Keep
      ignitor   cable  dry.
5.   Replace   ignitor  cable.
6.   Replace   piezo ignitor.
1.   Turn    on    gas    supply    of   open
      equipment  shutoff  valve.
2.  Fully   press   in   control   knob
      while  pressing  ignitor  button.
3.   Continue   holding    down    control
knob.  Repeat  igniting  operation
      until  air  is  removed.
4.   Clean ODS/pilot  (see Cleaning  and
     Maintenance, Page  13)   or
replace  ODS/pilot  assembly.
5.  Replace  gas  regulator.
6.  Turn controlknob  to  PILOT  position.
1.   Press in control knob fully.
2.   After  ODS/pilot lights, keep control
      knob  pressed  in  30  seconds.
3.    Fully  open equipment shutoff valve.
4.  Hand   tighten   until   snug,   then
      tighten 1/4  turn more.
5.    A)  Contact    local    natural    gas
             company.
      B)  Clean   ODS/pilot (see  Cleaning
            and   Maintenance, Page 13) or
           replace  ODS/pilot  assembly.
6.   Replace   thermocouple.
7.   Contact Dealer or PRO-COM.