Yamaha Robotics Robot Controller CC-Link Unit Manual Do Utilizador

Página de 76
3-
8
Communication
3
5. Referring to communication data
The ON/OFF information exchanged with the master station PLC can be referred to using the program-
ming unit (hereinafter, MPB).
Note that the MPB display update interval is longer than the CC-Link data update interval, so if the ON/
OFF interval is short, accurate information may not be displayed.
5.1
Referring to the data from the programming unit
The data exchanged with the master station PLC can be referred to with the MPB. The
reference unit is the robot controller input/output port No.
SYSTEM
V8.01
SI monitor
 SI0()=&B00000111
SI4()=&B11000000
 SI1()=&B00001111
SI5()=&B00101000
 SI2()=&B00010001
SI6()=&B00000111
 SI3()=&B00000100
SI7()=&B00000000
PARAM
CMUOPTION
INIT
DIAGNOS
* &Bxxxxxxx corresponds to the 0th bit to 7th bit from right to left.
SIW monitor
 SIW(0)=&H0132     SIW(4)=&H0000
 SIW(1)=&H0001     SIW(5)=&H0000
 SIW(2)=&H8000     SIW(6)=&HFFFF
 SIW(3)=&H0000     SIW(7)=&H0000
PARAM
CMUOPTION
INIT
DIAGNOS
SYSTEM
V8.01
* &Hxxxx expresses a hexadecimal.
[Operation]
1. Press the 
DISPLAY
 key. A screen like that shown below will appear.
SYSTEM
V8.01
DI monitor
 DI0()=&B00000111
DI4()=&B11000000
 DI1()=&B00001111
DI5()=&B00101000
 DI2()=&B00010001
DI6()=&B00000111
 DI3()=&B00000100
DI7()=&B00000000
PARAM
CMUOPTION
INIT
DIAGNOS
2. Press the 
DISPLAY
 key several times to check the status of SI input ports 0 to 7.
3. Press the 
DISPLAY
 key more to check the status of SI input ports 10 to 15.
4. Press the 
DISPLAY
 key twice more to check the status of SO input ports 0 to 7.
5. Press the 
DISPLAY
 key more to check the status of SO input ports 10 to 15.
6. Press the 
DISPLAY
 key twice more to check the status of SIW input ports 0 to 7.
7. Press the 
DISPLAY
 key more to check the status of SIW input ports 8 to 15.
8. Press the 
DISPLAY
 key more to check the status of SOW output ports 0 to 7.
9. Press the 
DISPLAY
 key more to check the status of SOW output ports 8 to 15.
10. To stop checking the input/output ports, press the 
ESC
 key.