electrical  connection
ELECTRICAL REQUIREMENTS
•  This appliance must be properly installed and grounded by a qualified technician in 
accordance with the National Electrical Code ANSI/NFPA No.70 (latest edition) and 
local  electrical  code  requirements.  IN  CANADA:  Electrical  installation  must  be  in 
accordance with the current CSA C22.1 Canadian Electrical Codes Part1 and/or local 
codes.
•  This appliance may be connected by means of permanent “Hard Wiring” or “Power 
Supply Cord Kit”. Power supply cord is not supplied, but it is available through your 
local electric supply house.
•  Use  only  3-conductor  or  4-conductor  CSA/UL  listed  range  cord  rated  at  55  amps 
with 250 V minimum and provided with ring terminals. These cords should be pro-
vided with strain relief or conduit connector.
  Warning: Frame grounded through neutral lead. If used in,
  - New branch-circuit installations (1996 NEC),
  - Mobile homes,
  - Recreational vehicles, or
- In an area where local codes prohibit grounding through neutral, use a 4 conductor 
cord or conduit.
•  The  range  must  be  connected  to  the  proper  electrical  voltage  and  frequency  as 
specified on the rating plate.
•  The range can be connected directly to the fused disconnect (or circuit breaker box) 
through flexible, armoured or non-metallic sheathed, copper cable (with grounding 
wire). Allow two to three feet of slack in the line so that it can be moved if servicing 
is ever necessary.
ELECTRICAL CONNECTION WITH POWER CORD
Use a 3-wire power supply cord kit rated for 55 amps - 125/250 Volts with closed loop 
terminals and marked for use with ranges. Where local codes do not permit grounding 
through neutral, use a 4-wire power supply cord kit.
The cord or CSA/UL-listed conduit must be secured to the range with the strain relief 
supplied or with a suitable strain relief. The electrical connection is made at the terminal 
block, which is located behind the access door on the back of the range.
ELECTRICAL CONNECTION WITH CONDUIT
Use  3/4”  (1.90  cm)  trade  size  conduit  with  a  conduit  clamp,  10  AWG/600  Volt  cop-
per conductor colored red for line 1 and black for line 2 and 12 AWG/600 Volt copper 
conductor (or 10 AWG/600 Volt copper conductor if grounding through neutral) colored 
white for neutral with closed loop terminals marked for use with ranges.
Where  local  codes  do  not  permit  grounding  through  neutral,  use  a  green  10  AWG 
copper conductor as directed in the 4-wire connector directions. The conduit must be 
secured to the range with the strain relief bracket. The electrical connection is made at 
the terminal block which is located behind the access door on the back of the range.
TO  AVOID  ELECTRICAL  SHOCK 
HAZARD,  BEFORE  INSTALLING  THE   
APPLIANCE,  SWITCH  POWER  OFF  AT 
THE  SERVICE  PANEL  AND  LOCK  THE 
PANEL  TO  PREVENT  THE  POWER 
F R O M   B E I N G   S W I T C H E D   O N  
ACCIDENTALLY.
WARNING