Chapter 7: Troubleshooting 
44 of 55 
Problem  
Possible cause  
Corrective action 
Field contact jumper (J1) has not 
been removed.  AUTO MODE. 
Remove jumper and wire the 
terminals to the processing 
machine relay. 
Field contact to the processing 
machine has failed. 
Check wiring/check the relay on 
the processor. 
Motor switch has failed. 
Replace. 
Field contact to process machine 
missing or loose. 
Correct. 
Control relay has failed. 
Replace. 
Motor control has failed. 
Replace. 
Optional timer set incorrectly. 
Reset. 
Motor will not stop. 
Optional timer has failed. 
Replace. 
Signal from motor speed sensor 
missing. 
Secure the sensor connections. 
Motor control has failed. 
Replace. 
Motor speed sensor has failed. 
Replace. 
Motor runs only at maximum 
speed. 
Motor speed sensor magnet 
misaligned. 
Adjust. 
Intermittent signal from motor 
speed sensor. 
Secure the sensor connections. 
Motor speed sensor has failed. 
Replace. 
Motor control has failed. 
Replace. 
Motor speed not constant. 
Material flow problem. 
Inspect for blockage, etc. 
Additive is contaminated by 
color from previous run. 
Feeder was not cleaned 
adequately prior to operation. 
See Section 6-2 on Page 39 for 
cleanout instructions. 
Power not applied 
Using a volt meter, verify that a 
voltage is measured between the 
L and N terminal block 
positions. 
 
Display is blank. 
Defective unit. 
Contact technical service. 
Display is dim. 
Display intensity.  
Check wiring/check the relay on 
the processor.