Siemens TV Converter Box 611 Manual Do Utilizador
Technical data and characteristics
14.2 Data sheets and diagrams
Technical data
1FW6160
1FW6160
Symbol
Unit
-xxB07-1Jxx -xxB07-2Jxx -xxB07-5Gxx
Data for precision motor cooler *)
Maximum dissipated thermal power
Q
P,MAX
kW
0.291
0.292
0.294
Recommended minimum volume flow
P,MIN
l/min
1.8
1.8
1.8
Temperature increase of the coolant
ΔT
P
K
2.3
2.3
2.3
Pressure drop
Δp
H
bar
0.4
0.4
0.4
*) Parallel connection of main and precision motor cooler
Table 14- 15 1FW6160-xxB07-8Fxx
Technical data
1FW6160
1FW6160
Symbol
Unit
-xxB07-8Fxx
Boundary conditions
DC link voltages
U
ZK
V
600
Water cooling inlet temperature
T
VORL
°C
35
Rated temperature of winding
T
N
°C
130
Rated data
Rated torque
M
N
Nm
432
Rated current
I
N
A
51
Maximum speed at rated torque
n
MAX,MN
rpm
610
Rated power dissipation
P
V,N
kW
3.73
Limit data
Maximum torque
M
MAX
Nm
1000
Maximum current
I
MAX
A
140
Electric power of motor at M
MAX
P
EL,MAX
kW
46.7
Maximum speed at maximum torque
n
MAX,MMAX
rpm
330
No-load speed
n
MAX,0
rpm
770
Torque at n = 1 [rpm]
M
0
Nm
653
Current at M
0
and n = 1 [rpm]
I
0
A
80
Thermal static torque
M
0
*
Nm
462
Thermal stall current
I
0
*
A
55
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
8.34
Voltage constant
k
E
V/(1000/min)
504.3
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
11
Thermal time constant
t
TH
s
180
No. of pole pairs
p
-
35
Cogging torque
M
COG
Nm
3.3
Stator mass
m
S
kg
36.2
Rotor mass
m
L
kg
12.1
1FW6 Built-in torque motors
232