Nortel Networks Water System BCM 1000 Manual Do Utilizador

Página de 86
Appendix G Market profile attributes
83
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Table 29   Loop interface and call supervision parameters
Market profile
Loop interface
Call supervision
Loop current 
limit
Ringing 
frequency
Ringing 
amplitude
Min. seize 
duration
Min 
answer 
duration
Min/max 
recall 
duration
Min clear 
duration
Australia
32 mA
25 Hz
65 Vrms
200 ms
50 ms
30/150 ms
1500 ms
Canada
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
Caribbean
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
Global
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
Hong Kong
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
Mexico
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
New Zealand
32 mA
25 Hz
65 Vrms
200 ms
50 ms
25/150 ms
1500 ms
North America
32 mA
20 Hz
65 Vrms
200 ms
25 ms
250/1100 
ms
1400 ms
Poland
32 mA
25 Hz
65 Vrms
180 ms
80 ms
51/88 ms
550 ms
United Kingdom
32 mA
25 Hz
65 Vrms
200 ms
50 ms
25/150 ms
1500 ms
Table 30   Dial pulse and DTMF parameters
Market profile
Dial pulse
DTMF
Dial pulse 
coding 
scheme
Min/max 
break 
duration
Min/max 
make 
duration
Min interdigit 
pause 
duration
DTMF coding 
scheme
Min DTMF 
detect level
Australia
N
25/120 ms
10/90 ms
250 ms
16 digits
-25 dB
Canada
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
Caribbean
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
Global
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
Hong Kong
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
Mexico
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
New Zealand
N
15/200 ms
15/200 ms
200 ms
16 digits
-25 dB
North America
N
25/120 ms
10/90 ms
250 ms
12 digits
-25 dB
Poland
N
51/88 ms
25/48 ms
150 ms
12 digits
-29 dB
United Kingdom
N
15/200 ms
15/200 ms
200 ms
16 digits
-25 dB