THE NIMBUS MN-800 TF REVERSE OSMOSIS TREATMENT SYSTEM
 
 
The Nimbus MN-800 TF is the perfect system for a wide variety of applications.  Features include 
stainless steel pressure vessels, frame and concentrate recirculation valve.  There are pressure 
gauges on the pre-filter outlet, post-filter inlet and the high pressure outlet of the desalinator array. 
 The MN-800 TF is also equipped with a 20" 10µ (micron) carbon cartridge pre-filter and post-
filter.  An Auxiliary 10” Post Filter with a Calcite element is included in the product line of one 
desalinator.   MN-800 TF systems have a nominal production rate of 800 gallons per day. 
§1.0  MN-800 TF SYSTEM SPECIFICATIONS 
 
MODEL NO. 
  MN-800 TF 
Membrane Type 
 
Thin Film 
No. of Desalinators 
 
2 (2525)  
Production Rate † (GPD) 
800  
Production Rate † (ml/min) 
2,103  
Maximum Operating Pressure (PSI) 
200  
Maximum Recovery 
 
33% 
Electrical Supplies 
110V/60 Hz 
11.0 A 
  220V/60 Hz 
5.2 A 
   
 
   
 
Motor Rating 
 
3/4 HP 
Pump Model 
       2504 A 
Dimension 
42”H x 19”W x 16”D 
Weight 84 
lbs 
 
    † 
Production rates are based on 200 psi net working pressure at 77
°
F with feed water containing 1000 ppm 
NaCl.  Flow tolerances are ± 15%. 
§2.0  SYSTEM COMPONENTS (See Figure 1) 
 
DESALINATOR: This is where the dissolved solids are separated from the feed water.  This 
assembly consists of a 316 stainless steel pressure vessel that houses the reverse osmosis (RO) 
membrane.   The MN-800 TF models come equipped with a Thin Film (TF) Membrane. 
 
PUMP/MOTOR ASSEMBLY: The rotary positive displacement pump boosts water pressure in the 
desalinator to about 185 psi (12.8 bar) to ensure high solids rejection and high flow rates. 
 
SOLENOID VALVE: Electrically operated valve that prevents water from flowing through the 
system when it is not in operation.