Compex Systems SA33-3285-02 Manual Do Utilizador

Página de 531
Installing a Replacement Disk Drive
1. Physically install the replacement disk drive (see the Operator Guide or Service
Guide for the unit).
2. If the failed disk drive has been exchanged for a hot spare disk drive, change the
use of the new disk drive to Hot Spare Disk (see “Changing or Showing the Use
of an SSA Disk Drive” on page 144). 
Run system diagnostics to verify that the disk
drive is working correctly.
If no hot spare disk drive was available when the original disk drive failed, the
array is now in the Exposed state or in the Degraded state. Change the use of the
new disk drive to Array Candidate Disk (see “Changing or Showing the Use of an
SSA Disk Drive” on page 144), 
and continue with this procedure to add the new
disk drive to the array.
3. For fast path, type
smitty exssaraid
and press Enter.
Otherwise:
a. Select Change Member Disks of an SSA RAID Array from the SSA RAID
Arrays menu.
b. Select Swap Members of an SSA RAID Array.
4. A list of arrays is displayed:
Change Member Disks of an SSA RAID Array
Move cursor to desired item and press Enter.
Remove a Disk from an SSA RAID Array
Add a Disk to an SSA RAID Array
SwapMembers of an SSA RAID Array
--------------------------------------------------------------------------
|
SSA RAID Array
|
|
|
| Move cursor to desired item and press Enter.
|
|
|
|
hdisk3
00703795D3F7C0G system good
9.2GB raid_1
|
|
hdisk4
00703784C540C0O system degraded
27.5GB raid_10
|
|
hdisk5
007037943540C0O system good
27.5GB raid_10
|
|
|
| F1=HelpF2=Refresh
F3=Cancel
|
| F8=Image
F10=Exit
Enter=Do
|
| /=Find
n=Find Next
|
--------------------------------------------------------------------------
Select the array into which you are installing the replacement disk drive. This array
is listed as exposed or degraded.
Chapter 6. Using the RAID Array Configurator
95