Compex Systems SA33-3285-02 Manual Do Utilizador

Página de 531
Effects of Array Copy on Other SMIT Menus
This section shows SMIT menus that are described elsewhere in this book. When Array
Copy is used, however, additional fields or display panels are present.
Change/Show Attributes of an SSA RAID Array
The following information is displayed for RAID-1 or RAID-10 arrays:
Change/Show Attributes of an SSA RAID Array
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[TOP]
[Entry Fields]
SSA RAID Manager
ssa1
SSA RAID Array
hdisk2
Connection Address / Array Name
8A8E39195F60C4O
RAID Array Type
raid_10
State
good
Copy State
copying
Size of Array
18.2GB
Primary Disks
pdisk0 pdisk6
Secondary Disks
pdisk9 pdisk10
Copy Disks
pdisk11 pdisk12
Percentage Rebuilt
Not Rebuilding
Percentage Copied
1
Split Array Resolution
Primary
+
Enable Use of Hot Spares
yes
+
[MORE...4]
F1=HelpF2=Refresh
F3=Cancel
F4=List
F5=Reset
F6=Command
F7=Edit
F8=Image
F9=Shell
F10=Exit
Enter=Do
The meanings of the additional fields are:
Copy State
The operational state of the array copy:
Not Copying
No copy is being created for this array.
Good
The coupled disk drives contain an exact copy of the data that is on
the array. The copy must be in the Good state before it can be
uncoupled from the array.
Copying
Data is being copied to the coupled disk drives, but these coupled
disk drives do not yet contain an exact copy of the data that is on the
array.
Degraded
A copy has been created, but one or more coupled disk drives are
missing or have failed. If missing disk drives are replaced or
exchanged for new disk drives, the copy operation continues.
Coupled Disks
The disk drives that are coupled to the array and contain the copy of the array
data. These disk drives are present only if an array copy has been created.
186
User’s Guide and Maintenance Information
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|