6.2.2 CAPACITY SETTING 
 
Press the [Hold] key to enter the calibration. Simply place the calibration 
mass to set up. Suggested value of the calibration mass is 50kg. 
However for higher accuracy the calibration mass should be as high as 
possible, maximum being 250kg. Press the [Func]  key to enter the 
same figures as the calibration mass used. The display will show 
“000000” when the calibration is complete. Press the [Hold]  key to 
return to weighing function. 
 
While setting use the keys as follows- 
 
[kg/lb] key  
: Triangular cursor moves left  
[Tare/Zero] key  : Triangular cursor moves right  
[Func] key  
: for figures setting (1-9) 
[Hold] key   
: to confirm 
 
7.0 TECHNICAL 
PARAMETERS 
 
The technical parameters are accessed by opening the scale and hence 
should be used only by the authorised technicians.   
 
Move the jumper on the main PCB to “KB1” position and turn on the 
scale when there is no load on the platform. Display will show: 
 
n   2000 
 
n” means: division  
3 settings: ”2000”, ”2500” & ”3000” to choose from.  Press 
[Hold] to confirm. 
d     1       “d” means: division value 
3 settings: ”d=1”, “d=2” & “d=5” to choose from.   
Press [Hold] to confirm 
dp   1   
“dp” means: decimal point 
4 settings for choose from: “0”, ”1”, ”2” & ”3” 
Press [Hold] to confirm and enter to weight setting (all 
decimal points are lighted up, set the Zero (the platform 
should be empty). 
000000
All decimal points are grey, small cursors are on, make the 
maximum capacity setting. Put the mass on the platform and 
then press the [Hold] key and wait                                     for 
“END” to be displayed. 
END
Lastly, switch the jumper to the original location.