Delta Tau GEO PMAC Manual Do Utilizador

Página de 117
 
Geo PMAC Drive User Manual 
26 
System Wiring 
 
Caution: 
The black wires are for the thermostat and the white wires are for the regen resistor 
on the external regen resistor (pictured below).  These resistors can reach 
temperatures of up to 200 degrees C.  These resistors must be mounted away from 
other devices and near the top of the cabinet.  Additionally, precautions must be 
made to ensure the resistors are enclosed and cannot be touched during operation 
or anytime they are hot.  Sufficient warning labels should be placed prominently 
near these resistors. 
The GAR regen resistors incorporate a thermal overload protection thermostat that opens when the core 
temperature of the resistor exceeds 225 degrees C.  This thermostat is available through the two black 
leads exiting the resistor.  It is important that these two leads be wired in a safety circuit that stops the 
system from operating should the thermostat open.   
 
J5:  External Shunt Connector Pinout 
Pin # 
Symbol 
Function 
1 Regen- 
Output 
2 Regen+ 
Output 
Connector is located at the top side of the unit 
DT Connector part number #014-000F02-HSG and pins part number #014-043375-001 
Molex Crimper tool p/n#63811-0400 
For the high Current Drives,  Gxx201xx and Gxx301xx , this connector is a 3 pin Large 
Molex connector  
1 CAP- 
Output 
2 Regen- 
Output 
3 Regen+ 
Output 
Connector is located at the top side of the unit. 
DT Connector part number #014-H00F03-049 and pins part number #014-042815-001. 
Molex Crimper tool p/n#63811-1500