DCS none Manual Do Utilizador

Página de 18
dCS Scarlatti Clock User Manual 
Software Issue 1.0x 
 
June 2008 
  
   
 
 
Filename: Scarlatti Clock Manual v1_0x.doc 
Page 16
 
 English version 
 
 M
AINTENANCE AND 
S
UPPORT
 
 Service and Maintenance 
dCS audio products are designed not to need regular maintenance, and contain no user serviceable 
parts apart from the mains fuse. If your unit is damaged in any way, please contact your dealer. 
 
 Replacing a Blown Mains Fuse 
There is a mains fuse below the power inlet, accessible from the outside of the unit. If the fuse blows, 
it may be changed by the user. The current consumption of the unit is very low, so it only blows if 
power surges occur, or there is a fault in the unit. Usually power surges cause no other damage, but if 
the fuse blows repeatedly on replacement, some other damage will have been done and the unit must 
be returned to dCS for repair. 
Fuse type: 20 x 5mm T0.5 amp L fuse 
!
 
If the fuse should fail, it is essential that it is replaced with one of the same type and 
rating. Failure to do so could result in damage to the unit, risk of fire or electric shock and 
will invalidate the guarantee. 
Referring to the diagram below, remove the power cable, use a small flat bladed screwdriver to pry up 
the tab on the fuse carrier (A) and pull it out. Push the blown fuse out of the clip in the carrier (B) and 
dispose of it. Fit a new fuse in the clip (C) and push the carrier back into the unit so that it clicks home. 
Spare fuses are provided with the unit.  
C
B
A
 
 
 Cleaning the case 
The front and back panels of your dCS equipment are machined from very high grade aluminium. 
Great care has been taken to create the finish of the aluminium throughout the engineering process 
from the raw solid material to the finished piece. 
To remove loose dust or finger marks from the case, we recommend that you use a clean, dry, lint-
free cloth. 
To restore the finish on the front and back panels, we recommend applying small quantities of a 
lanolin based cleaner, using a clean, dry, lint-free cloth and then wiping off. Do not allow lanolin to 
collect around the buttons. 
Small amounts of glass cleaner containing ammonia may be used to clean other surfaces, but avoid 
spraying onto the connector contacts.