Breckwell W3000 Manual Do Utilizador

Página de 13
SPECIAL MOBILE / MANUFACTURED HOME 
REQUIREMENTS 
 
WARNING: Do not install in a sleeping room. 
 
For installation in a mobile/manufactured home, the 
outside air kit must be used. 
(See “OUTSIDE AIR KIT – W3000FS ONLY”)
 
 
The W3000FS must be securely fastened to the floor 
of the mobile (manufactured) home using the 
mounting bolt holes located in the pedestal of the 
W3000FS. Use only the holes provided. 
 
If the optional blower is used the W3000FS must be 
grounded to the steel chassis of the home with 8 Ga. 
Copper wire using a serrated or star washer to 
penetrate paint or protective coating to ensure 
grounding. 
 
WARNING: DURING THE INSTALLATION OF THIS 
STOVE, DO NOT COMPROMISE THE 
STRUCTUARL INTEGRITY OF THE MOBILE 
(MANUFACTURED) HOME WALL(S), FLOOR OR 
CEILING. 
 
INSTALLING THE BRICK PANELS 
 
The brick panels will come already installed in the 
W3000. The following directions are included should 
you ever need to remove and re-install the brick 
panels. 
 
Wearing gloves is recommended when  handling the 
brick panels. 
 
Install  the brick panels shown in figure 6 in the 
following order: C, A (rear), D, A (bottom). Next install 
the ‘B’ panels on the secondary tubes. 
(See figures 7 & 8) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION 
FIGURE 6 
FIGURE 7 
FIGURE 8 
BRICK SIZES 
 
A = 10” x 12” 
B = 9-3/4” x 15-1/4” 
C = 9” x 7-7/8” 