This document outlines the power supply specification of MB-3Useries.
2.  Applicable Documents:
See ATX Specification Version 2.03/_12V version 2.3 and Intel ATX Power Supply Design 
 Guide EPS/SSI Version 2.91. 
3.  Electric specification:
The electrical requirements that follow are to be met over the environmental ranges specified in
Section 5 unless otherwise noted.
  3.1 AC input requirement:
    3.1.1 AC input requirement:
a.
The power supply shall be capable of supplying full rated output power over two 
input voltages ranges rated 115Vac and 230Vac RMS nominal at 0℃ ~ 50℃.
            b
Input voltage range
Input frequency range
Selecting
85Vac ~ 135Vac
47Hz ~ 63Hz
Select switch
170Vac ~ 265Vac
47Hz ~ 63Hz
Select switch
            c.  Auto range:
**option.
            d.  PFC function        **optional
                 *For Active   PFC Vin=100~240Vac  full-range,  PF=0.95min.
                 *For Passive PFC Vin=115/230Vac   by-switch,   PF=0.85 typ.
3.1.2    AC  over current Protection:
The power supply shall incorporate primary fusing for input overcurrent protection. Fuses
should be slow-blow type or equivalent to prevent nuisance trips.
3.1.3  Inrush Current Limiting:
Maximum inrush current from power-on (with power on at any point on the AC Sine) and
including, but not limited to, three line cycles, shall be limited to a level below the surge
rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter
components. Repetitive ON/OFF cycling of the AC input voltage should not damage the
power supply or cause the input fuse to blow.
3.1.4  Input under voltage:
The power supply shall contain protection circuitry such that the application of an input
voltage below the minimum specified in Section 3.1, Table 1, shall not cause damage to
the power supply.
3.1.5 Electrical fast transient/burst:
No unsafe operation is allowed under any condition. No user-noticeable performance
degradation up to +- 1 kV Mains, +- 500V Signal Cable, is allowed. Automatic or manual
recovery is allowed for other conditions.