VI.  STARTING THE UNIT 
FLAME MUST BE 
DETECTED WITHIN 
4 SECONDS IF FLAME 
IS DETECTED, THE 
DELAY-TO-FAN-ON 
TIME BEGINS (45 SECONDS)
IF FLAME IS NOT 
DETECTED, THE GAS VALVE 
IS DE-ENERGIZED, THE 
IGNITOR IS TURNED OFF AND 
THE CONTROL BOARD CONTROL 
GOES INTO "RETRY" SEQUENCE
POWER IS APPLIED TO 
THE SILICON NITRIDE 
IGNITOR.  IGNITOR 
WARM-UP IS 20 SECONDS
POWER INTERRUPTION 
SYSTEM SHUTS OFF, 
RESTARTS WHEN 
POWER IS RESTORED.
PRESSURE SWITCH SENSES
ADEQUATE DIFFERENTIAL
PRESSURE CONTACTS CLOSE
THERMOSTAT CALLS FOR 
HEAT, CONTACTS CLOSE
CONTROL BOARD ENERGIZED,
INDUCER ENERGIZED
CONTINUOUS SAFE OPERATION CHECK IF FLAME 
SIMULATION CONDITION PRESENT OR ROLL-OUT
SWITCH OPENS, SYSTEM ENERGIZES INDUCER
FAN FOR 15 SECONDS AND CIRCULATOR BLOWER
AT HEATING SPEED UNTIL SITUATION CORRECTION
AT ANY TIME THE
GAS VALVE IS 
NOT ENERGIZED
A. SEQUENCE OF OPERATIONS
START TRIAL
FOR IGNITION
START
AFTER IGNITOR WARM-UP,
THE GAS VALVE IS 
ENERGIZED TO OPEN