All installations and services must be performed by qualified service personnel.
 
 33
DIAGNOSTIC FEATURES 
 
: Power must be disconnected before servicing. 
 
The 50A65-143 control continuously monitors its own operation and the operation of the 
system.  If a failure occurs, the LED will indicate a failure code as shown below.  If the 
failure is internal to the control, the light will stay on continuously.  In this case, 
the entire control should be replaced, as the control is not field-repairable.
 
 
If the sensed failure is in the system (external to the control), the LED will flash in the 
following flash-pause sequences to indicate failure status (each flash will last 
approximately 0.25 seconds, and each pause will last approximately 2 seconds). 
 
1 flash, then pause   
System lockout 
2 flashes, then pause 
 
Pressure switch stuck closed 
3 flashes, then pause 
 
Pressure switch stuck open 
4 flashes, then pause 
 
Open limit switch or rollout switch 
6 flashes, then pause 
 
115 Volt AC power reversed 
7 flashes, then pause 
 
Low flame sense signal 
8 flashes, then pause 
 
Check igniter or improper grounding 
 
Continuous flashing  
Flame has been sensed when 
(No pause)   
 
no flame should be present 
 
 
 
    (No 
call 
for 
heat) 
 
 
 
 
 
The LED will also flash once at power-up.