7.0 System 
Maintenance 
Features 
System Maintenance features include Flash Memory Update and Restore Factory 
Settings. These options require the system be taken out of service for 
maintenance. 
The System Setup options are also accessible from the Main Menu Screen, by 
pressing the F1 key to access the System Setup submenu. System Options 
include  System Flash Memory Update (F) and Load Factory Settings (F12)
Other options listed there are for FUTURE USE and should not be attempted.  
Caution:  Do NOT use System Setup Options during normal operation, as these 
can erase all user-entered data and will require a system power reset to restore 
normal operation.  
7.1  Setting Factory Defaults 
If it becomes necessary to reset the PC ServerSwitch 2x16 to its factory-set 
values, the users may do so from the 
System Setup
System Setup
System Setup
System Setup menu. The System must be 
out of service during this procedure. All connections will be dropped, and all default 
values will be restored. The whole process takes less than 5 minutes.  
1. Access the 
System Setup
System Setup
System Setup
System Setup menu by pressing Cntl-Cntl on any attached 
keyboard, or pressing the Scroll Lock key twice.  
2.  Once at the 
System Setup
System Setup
System Setup
System Setup menu, access the System Setup submenu by 
pressing the 
<F1>
<F1>
<F1>
<F1> key.  
3. Press the 
<F12>
<F12>
<F12>
<F12> key. You are prompted "Are You Sure?", and then press 
the 
Y
Y
Y
Y key to confirm that the PC ServerSwitch 2x16 parameters and server 
port names should be set to the factory default values. If not, press 'N' to 
exit this option.  
4.  The Display will change to 'Restoring Factory Defaults'. Then, the on-screen 
menu will temporarily disappear, and reappear at the main on-screen menu 
once the parameters are reset. The front LCD display will show "Save 
Database" when it is completing the update.  
The ServerSwitch will not be able to switch to another port or pass 
keyboard/mouse signals during the reset to factory defaults. 
7.2  Flash Update Procedure 
The flash update feature allows the user to install newer versions of operating 
software in the PC ServerSwitch 2x16 without removing the unit from its installation 
(the system must be removed from service, however). New software revisions will 
be released from time to time to add features to the PC ServerSwitch 2x16 or 
make changes for customer requests. Note that the users will not be able to switch 
server ports during the update. The whole process takes less than 10 minutes.  
The binary file for the flash update can be downloaded from  
ftp://ftp.lightwavecom.com/pub/products/PCSS2x16/software/