a soap and water solution.
Do not use a flame to check
for leaks. After verifying that
there are no gas leaks, turn off
the gas supply to the cooktop
by turning the gas shut-off
valve to the off position. Leak
testing of the appliance shall
be conducted according to the
manufacturer’s instructions.
6. For LP gas installations, the
LP gas tank must have its own
high-pressure regulator. This
is in addition to the pressure
regulator supplied with the
cooktop.
Attach the gas pressure regulator (included with
the cooktop) to cooktop pipe nipple inlet. For
tight installations, the regulator may be installed
upstream from the pipe nipple, anywhere
between the shut-off valve and the cooktop.
Install a gas shut-off valve (not included with
the cooktop) in the main gas supply line in an
accessible location near the cooktop. Complete
connection of the gas supply to the cooktop
by installing 1/2 inch flexible gas line (not
included with the cooktop) between the pressure
regulator and the shut-off valve.
IMPORTANT:
To prevent damage to the gas
pressure regulator, install the
regulator only after the cooktop
is mounted in its permanent
position. Ensure that the arrow
on the regulator points in the
direction of the gas flow towards
the cooktop.
Installing the Burner and Grill
Components
WARNING:
Never attempt to operate the
cooktop with any of the burner
rings, burner caps, grates, or grill
components removed.
SGM Burner Components
Remove the brass burner rings, porcelain burner
caps, and porcelain grates from their shipping
packages. Place each burner ring onto its
corresponding burner base, being certain that
the five alignment tabs slide into the matching
notches in the base. Set each porcelain burner
cap on top of its corresponding burner ring.
Place each grate onto the cooktop, being certain
that the rubber feet are positioned in the locating
dimples.
Grill Components
Remove the grill components from inside
the main carton. Remove all of the packing
materials from the Grill, U-burner, Heat Control
Channels, Grease Control Box and the Drip
Pans.
Begin your set up by placing the Drip Pans
inside on the bottom of the open grill burner
box area, using the dimples to locate the Drip
Pan. Next, slip the open end of the U-burner
onto the gas stub located in the front inside of
the grill burner box, and insert the bracket on
to opposite end of the U-burner into the slot
located on the Grease Control Box.
Proceed to install the Heat Control Channels,
which sit on top of four pins at the inside front
and back of the grease control box. Finally, set
the grill in place on the top of the cooktop.
Grate
Burner Cap
Burner Ring
Top Frame
Burner Head (Fixed)
SGM Burner Components
NOTE:
The U-burner is adjusted at the
factory and does not require
any field adjustment for proper
function.
Electrical Connection
Electrical Connection
WARNINGS:
1. Ensure that the power supply
is disconnected before
proceeding.
2. Verify that the power supply
matches the ratings found on
the appliance data plate before
proceeding.
3. The complete appliance must
be properly grounded at all
times when electrical power is
applied.
4. Do not ground the appliance
with the neutral (white) house
supply wire. A separate
ground wire must be utilized.
5. If aluminum house supply
wiring is utilized, splice the
appliance copper wires to the
aluminum house wiring using
special connectors designed
and agency-certified for
joining copper and aluminum.
6. Follow the connector
manufacturer’s recommended
procedure carefully. Improper
connection can result in a fire
hazard!
Verifying Proper Operation
WARNINGS:
1. If the cooktop fails to operate
properly, ensure that the
electrical power supply and
gas supply are turned on and
that all installation steps have
been carefully followed. Call
a qualified service technician
if the cooktop still does not
operate properly.
2. The cooktop and shut-off
valve must be disconnected
from the gas supply piping
during any pressure testing
exceeding 1/2 pound per
square inch (3.5 kPA).
3. The cooktop must be isolated
from the gas supply piping
by closing the shut-off valve
during any pressure testing at
or below 1/2 pound per square
inch (3.5 kPA).
Before beginning the test procedure, ensure
that the gas supply is turned off at the shut-off
valve, all cooktop control valves are in the “OFF”
position, and all burner rings, burner caps, and
grates are properly positioned on the cooktop.
SGM Models
Rotate one knob at a time counterclockwise to
the “HIGH” position. Verify that all ignitors spark
continuously, then return the knob to the “OFF”
position. Repeat for all knobs.
Turn on the main gas supply to the cooktop by
opening the gas shut-off valve. Test each burner
separately by pressing and turning one control
knob at a time counterclockwise to the “HIGH”
position. On the SGM models, all ignitors will
spark simultaneously, but only the burner with
gas flowing to it will ignite. On the PGM model,
only the selected burner will spark. (It will take
approximately four seconds for ignition to occur,
at which time all ignitors will stop sparking. If
ignition does not occur within four seconds,
Plug the three-prong plug from the appliance
into the properly grounded and polarized wall
receptacle.
Off Position
Knob Position
Indicator
(Polished Surface)
Burner
Designation
Light & High
Position
Area of
Operation
Low
Position
Logo on Front
Knob Only
SGM Burner Control Valve