a soap and water solution. 
Do not use a flame to check 
for leaks. After verifying that 
there are no gas leaks, turn off 
the gas supply to the cooktop 
by turning the gas shut-off 
valve to the off position. Leak 
testing of the appliance shall 
be conducted according to the 
manufacturer’s instructions.
6.  For LP gas installations, the 
LP gas tank must have its own 
high-pressure regulator. This 
is in addition to the pressure 
regulator supplied with the 
cooktop.
Attach the gas pressure regulator (included with 
the cooktop) to cooktop pipe nipple inlet. For 
tight installations, the regulator may be installed 
upstream from the pipe nipple, anywhere 
between the shut-off valve and the cooktop.  
Install a gas shut-off valve (not included with 
the cooktop) in the main gas supply line in an 
accessible location near the cooktop.  Complete 
connection of the gas supply to the cooktop 
by installing 1/2 inch flexible gas line (not 
included with the cooktop) between the pressure 
regulator and the shut-off valve.
IMPORTANT:
To prevent damage to the gas 
pressure regulator, install the 
regulator only after the cooktop 
is mounted in its permanent 
position. Ensure that the arrow 
on the regulator points in the 
direction of the gas flow towards 
the cooktop.
Installing the Burner and Grill 
Components
WARNING: 
Never attempt to operate the 
cooktop with any of the burner 
rings, burner caps, grates, or grill 
components removed.
SGM Burner Components
Remove the brass burner rings, porcelain burner 
caps, and porcelain grates from their shipping 
packages. Place each burner ring onto its 
corresponding burner base, being certain that 
the five alignment tabs slide into the matching 
notches in the base. Set each porcelain burner 
cap on top of its corresponding burner ring. 
Place each grate onto the cooktop, being certain 
that the rubber feet are positioned in the locating 
dimples.
Grill Components
Remove the grill components from inside 
the main carton. Remove all of the packing 
materials from the Grill, U-burner, Heat Control 
Channels, Grease Control Box and the Drip 
Pans.
Begin your set up by placing the Drip Pans 
inside on the bottom of the open grill burner 
box area, using the dimples to locate the Drip 
Pan. Next, slip the open end of the U-burner 
onto the gas stub located in the front inside of 
the grill burner box, and insert the bracket on 
to opposite end of the U-burner into the slot 
located on the Grease Control Box. 
Proceed to install the Heat Control Channels, 
which sit on top of four pins at the inside front 
and back of the grease control box. Finally, set 
the grill in place on the top of the cooktop.
Grate
Burner Cap
Burner Ring
Top Frame
Burner Head (Fixed)
SGM Burner Components
NOTE: 
The U-burner is adjusted at the 
factory and does not require 
any field adjustment for proper 
function.
Electrical Connection
WARNINGS:
1.  Ensure that the power supply 
is disconnected before 
proceeding.
2.  Verify that the power supply 
matches the ratings found on 
the appliance data plate before 
proceeding.
3.  The complete appliance must 
be properly grounded at all 
times when electrical power is 
applied.
4.  Do not ground the appliance 
with the neutral (white) house 
supply wire. A separate 
ground wire must be utilized.
5.   If aluminum house supply 
wiring is utilized, splice the 
appliance copper wires to the 
aluminum house wiring using 
special connectors designed 
and agency-certified for 
joining copper and aluminum.
6.  Follow the connector 
manufacturer’s recommended 
procedure carefully. Improper 
connection can result in a fire 
hazard!
Verifying Proper Operation
WARNINGS:
1.  If the cooktop fails to operate 
properly, ensure that the 
electrical power supply and 
gas supply are turned on and 
that all installation steps have 
been carefully followed. Call 
a qualified service technician 
if the cooktop still does not 
operate properly.
2.  The cooktop and shut-off 
valve must be disconnected 
from the gas supply piping 
during any pressure testing 
exceeding 1/2 pound per 
square inch (3.5 kPA).
3.  The cooktop must be isolated 
from the gas supply piping 
by closing the shut-off valve 
during any pressure testing at 
or below 1/2 pound per square 
inch (3.5 kPA).
Before beginning the test procedure, ensure 
that the gas supply is turned off at the shut-off 
valve, all cooktop control valves are in the “OFF” 
position, and all burner rings, burner caps, and 
grates are properly positioned on the cooktop.
SGM Models
Rotate one knob at a time counterclockwise to 
the “HIGH” position. Verify that all ignitors spark 
continuously, then return the knob to the “OFF” 
position. Repeat for all knobs.
Turn on the main gas supply to the cooktop by 
opening the gas shut-off valve. Test each burner 
separately by pressing and turning one control 
knob at a time counterclockwise to the “HIGH” 
position. On the SGM models, all ignitors will 
spark simultaneously, but only the burner with 
gas flowing to it will ignite. On the PGM model, 
only the selected burner will spark. (It will take 
approximately four seconds for ignition to occur, 
at which time all ignitors will stop sparking. If 
ignition does not occur within four seconds, 
Plug the three-prong plug from the appliance 
into the properly grounded and polarized wall 
receptacle.
Off Position
Knob Position 
Indicator
(Polished Surface)
Burner
Designation
Light & High
Position
Area of
Operation
Low
Position
Logo on Front
Knob Only
SGM Burner Control Valve