Step 3: Setting Valve Screws 
for the STAR
®
 Burners
Screwdriver for valve screw setting:
The provided flat-head screwdriver is used to reposition the 
valve screws for minimum flow settings on the knobs.
Setting valve screws on ranges:
1. SHUT OFF THE GAS SUPPLY TO THE APPLIANCE 
AND DISCONNECT THE ELECTRICAL POWER.
2. Remove knob from the valve stem by slowly pulling 
knob straight out, away from the control panel.
3. Remove the bezel-mounting screw located to the right 
of the valve stem using a T-20 Torx screwdriver.
4. For ExtraLow
®
 valves, turn the valve stem to the LOW 
position for proper access to the valve screws through 
clearance holes in the XLO
®
 potentiometers.
5. To engage the valve screw, insert the included 
screwdriver with 1/8” blade into the hole in the bezel 
created by removal of the bezel-mounting screw.
WARNING:
Before proceeding with the adjustment, SHUT OFF 
THE GAS SUPPLY TO THE APPLIANCE PRIOR 
TO DISCONNECTING THE ELECTRICAL POWER.
If the information in this manual is not followed 
exactly, fire or shock may result causing property 
damage or personal injury.
Valve Screw
Valve screw access
Valve screw access
Valve screw access
hole with valve in 
OFF
hole with valve in 
OFF
hole with valve in 
OFF
position.
position.
position.
Valve screw access
Valve screw access
Valve screw access
hole with valve in 
LOW
hole with valve in 
LOW
hole with valve in 
LOW
position.
position.
position.